Zanussi ZCG91246 User Manual page 21

Table of Contents

Advertisement

Bypass diameters
BURNER
Auxiliary
Semi-rapid
Rapid
Triple Crown
Oven
Grill
Gas burners for NATURAL GAS G20 20 mbar
BURNER
Triple Crown
Rapid
Semi-rapid
Auxiliary
Oven
Grill
Gas burners for LPG G30 28-30 mbar
BURNER
Triple Crown
Rapid
Semi-rapid
Auxiliary
Oven
Grill
Gas connection
The gas pipe in the appliance has two endings.
You can connect the gas supply to either one of
them. The pipe that is not used must be
clogged with the pipe closer, which added to
the appliance.
www.zanussi.com
NORMAL POWER
kW
4.0
3.0
2.0
1.0
3.6
2.5
NORMAL POWER
kW
4.0
3.0
2.0
1.0
3.6
2.5
Ø BYPASS 1/100 mm
29 / 30
32
42
67
54
59
REDUCED POWER kW
1.8
0.72
0.43
0.35
1.5
1.6
REDUCED POWER kW
1.8
0.72
0.43
0.35
1.5
1.6
Use a fixed connections or use a flexible
stainless steel pipes in compliance with the
regulation in force. If you use flexible metallic
pipes, make sure they do not come in touch
with mobile parts and they are not squeezed.
INJECTOR MARK
1/100 mm
146
119
96
70
126
111
INJECTOR MARK
1/100 mm
101
88
71
50
90
80