1-4. Setting the Auto Restart
Enable or disable automatic system restart after a power outage.
Setting Description
Yes
No
1-5. Setting the Indoor room temperature sensor switching function
(Only for Wired remote controller)
The following settings are needed when use the control by
Wired remote controller temperature sensor.
Setting Description
No
Yes
* If setting value is "00" : Room temperature is controlled by the indoor unit temperature sensor.
* If setting value is "01" : Room temperature is controlled by remote controller unit sensor.
1-6. Setting the Remote controller signal code
Change the indoor unit Signal Code, depending on the remote controllers.
Setting Description
A
B
C
D
1-7. Setting the External input control
"Operation/Stop" mode or "Forced stop" mode can be elected.
Setting Description
Operation/Stop mode
(Setting forbidden)
Forced stop mode
1-8. Indoor unit fan control for energy saving (Only cooling mode)
Enable or disable indoor unit fan control when the outdoor unit is stopped.
Setting Description
No
Yes
* If setting value is "00" :
When the outdoor unit is stopped, the indoor unit fan operates following the setting
on the remote controller continuously.
* If setting value is "01" :
When the outdoor unit is stopped, the indoor unit fan operates at very low speed intermittently.
(
Function Number
Setting Value
40
(
Function Number
Setting Value
42
(
Function Number
Setting Value
44
(
Function Number
Setting Value
46
(
Function Number
Setting Value
49
03-02
Factory setting)
00
01
Factory setting)
00
01
Factory setting)
00
01
02
03
Factory setting)
00
01
02
Factory setting)
00
01