6-2.
HEATING CAPACITY
This table is created using the maximum capacity.
MODEL
: AUA30L
AFR
°CDB
-15
-10
-5
0
5
7
10
15
20
24
MODEL
: AUA36L
AFR
°CDB
-15
-10
-5
0
5
7
10
15
20
24
AFR : Air Flow Rate (m
3
/min)
TC : Total Capacity (kW)
IP : Input Power (kW)
26.7
°CDB
16
°CWB
TC
IP
-16
8.34
3.37
-11
8.79
3.38
-7
9.55
3.41
-2
10.12
3.37
3
11.23
3.35
6
11.76
3.33
8
12.12
3.30
10
10.86
2.52
15
10.87
2.23
18
11.31
2.25
30.0
°CDB
16
°CWB
TC
IP
-16
9.63
3.92
-11
9.70
3.96
-7
10.69
4.07
-2
12.54
3.99
3
13.18
3.81
6
13.34
3.36
8
13.74
3.19
10
12.26
2.55
15
12.28
2.26
18
12.80
2.28
- (01 - 11) -
Indoor temperature
18
20
TC
IP
TC
IP
8.14
3.44
7.94
3.51
8.58
3.45
8.37
3.52
9.32
3.48
9.09
3.55
9.88
3.44
9.64
3.51
10.96
3.42
10.69
3.49
11.48
3.40
11.20
3.47
11.83
3.37
11.54
3.44
10.60
2.57
10.34
2.62
10.61
2.28
10.35
2.33
11.04
2.30
10.78
2.34
Indoor temperature
18
20
TC
IP
TC
IP
9.40
4.00
9.17
4.08
9.47
4.04
9.24
4.13
10.43
4.16
10.18
4.24
12.24
4.08
11.94
4.16
12.87
3.89
12.55
3.97
13.02
3.43
12.70
3.50
13.42
3.26
13.09
3.33
11.97
2.60
11.67
2.65
11.99
2.31
11.69
2.36
12.49
2.32
12.19
2.37
22
24
TC
IP
TC
IP
7.75
3.58
7.55
3.65
8.16
3.59
7.95
3.66
8.86
3.62
8.64
3.69
9.40
3.58
9.16
3.65
10.43
3.56
10.16
3.62
10.92
3.54
10.64
3.61
11.25
3.51
10.96
3.57
10.09
2.67
9.83
2.71
10.09
2.37
9.83
2.41
10.51
2.39
10.24
2.43
22
24
TC
IP
TC
IP
8.94
4.17
8.71
4.25
9.01
4.21
8.77
4.29
9.92
4.33
9.67
4.41
11.64
4.24
11.34
4.33
12.24
4.05
11.92
4.13
12.38
3.57
12.07
3.64
12.76
3.39
12.43
3.46
11.38
2.71
11.09
2.75
11.40
2.40
11.11
2.44
11.88
2.42
11.58
2.46