Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 12/1/2017 8:00:00 AM
Test report #103124842MTL-001 (10 of 15)
Stove Builder International Inc.
Project No. G103124842
III.•
PROCESS•DESCRIPTION•
III.A• TEST•SET-UP•DESCRIPTON•
A 6" flue is connected to a standard 6" diameter vertical single wall pipe and insulated
chimney system was installed to 15' above floor level. The single wall pipe extended to 8
feet above the floor and insulated chimney extended the remaining height.
III.B• AIR•SUPPLY•SYSTEM•
Combustion air enters on the bottom of the heater, which is directed to the firebox. All
gases exit through the 6" flue located on top of the heater.
III.C• TEST•FUEL•PROPERTIES•
The species of fuel used was mainly maple. The fuel was split cordwood of nominal
length of 16 inches. The fuel was dried in air to average moisture content between 18%
and 28% on a dry basis. Cordwood fuel was loaded from side to side into the firebox per
manufacturer's instructions.
IV.•
SAMPLING•SYSTEMS•
IV.A.• SAMPLING•LOCATIONS•
Particulate samples are collected from the dilution tunnel at point 20 feet from the
tunnel entrance. The tunnel has two elbows and two mixing baffles in the system
ahead of the sampling section. (See Figure 3.) The sampling section is a continuous
13-foot section of 8-inch diameter pipe straight over its entire length. Tunnel velocity
pressure is determined by a type "S" Pitot tube located 100 inches from the beginning
of the sampling section. The dry bulb thermocouple is located six inches downstream
from the Pitot tube. Tunnel samplers are located 48 inches downstream of the Pitot
tube and 36 inches upstream from the end of this section. (See Figure 1.)
Stack gas samples are collected from the steel chimney section 8 feet ± 6 inches
above the scale platform. (See Figure 2.)
Stove Builder International Inc. | 35697 | Rev: Nov 30 2017 11:01AM | Uncontrolled Copy
Date: 21 July 2017
Page 10 of 15