Preparing For Operation - North Star M165912I.4 Owner's Manual

Portable, outdoor use-only, gasoline generator
Table of Contents

Advertisement

Position
Position generator in accordance with the instructions given in
"Installation & Initial Set-up, Step 4: Select a Suitable Site"
generator
manual.
Operate outside only, on dry, level ground with at least 20 feet from the home,
away from windows, vents and air intakes, to allow proper ventilation.
Ground
Make sure the generator is grounded in accordance with instruction given
generator
in
this manual.
Perform
Make sure that any regular maintenance has been performed as prescribed
in this manual in the "Maintenance & Repair" section.
scheduled
maintenance as
needed
Check/add oil
Check the oil level using the dipstick and add oil as needed.
Using a funnel, add oil up to the FULL mark on the dip stick with the
recommended oil type for your engine and expected ambient conditions.
(See engine Owner's Manual for oil type and capacity, and more detailed oil
check/fill instructions.)
˙Notes:
o Low oil shutdown feature prevents the generator from starting without sufficient oil.
o
IMPORTANT:
Under long, continuous-run operating conditions, be prepared to:
Check the gasoline level in the generator's tank. If needed, fill tank with
Check/fill
gasoline tank
fresh unleaded gasoline from a portable container, after first reading the
warnings and instructions below.
Operation (cont'd)

2. Preparing for Operation

WARNING: Carbon monoxide poisoning hazard
Generators give off carbon monoxide exhaust, a poisonous gas that can
kill. You CANNOT smell it, see it, or taste it. ONLY run generator
OUTDOORS and at least 20 feet from the home, away from windows,
vents and air intakes, to allow proper ventilation. If you start to feel sick,
dizzy, or weak while using the generator, shut off the engine and get to
fresh air RIGHT AWAY. NEVER run generator inside any enclosed or
semi-enclosed spaces, including homes, garages, basements, sheds,
boxes, pick-up truck beds, RVs, or boats. These spaces can trap
poisonous gases, EVEN if you run a fan or open windows. Carbon
monoxide exhaust is given off whether you are using gasoline, natural
gas, or propane to power the generator.
"Installation & Initial Set-up, Step 5: Grounding the Generator"
WARNING: Electric shock hazard
Always ensure generator is properly grounded to prevent electrical
shock.
Refer to the engine owner's manual for engine maintenance
instructions.
WARNING: Burn hazard
Never open oil port while engine is running. Hot oil can spray over face
and body.
Engine is shipped without oil. You must add oil before first use.
 Check engine oil level every time you refuel the engine.
 Change oil after the first 20 operating hours, and at least every 100
operating hours thereafter, or as directed in engine owner's manual.