Please read before proceeding

The Knight XL Installation and Operation
NOTICE
Manual along with the Knight XL Service
Manual are for use only by a qualified heating installer/
service technician.
Refer only to this User's Information
Manual for your reference. Improper installation, adjustment,
alteration, service or maintenance can cause property damage,
personal injury (exposure to hazardous materials) or loss of
life. Installation and service must be performed by a qualified
installer, service agency or the gas supplier (who must read and
follow the supplied instruction before installing, servicing, or
removing this boiler. This boiler contains materials that have
been identified as carcinogenic, or possibly carcinogenic, to
humans).
When calling or writing about the boiler
NOTICE
– Please have the boiler model and serial
number from the boiler rating plate.
Consider piping and installation when determining boiler
location.
Any claims for damage or shortage in shipment must be
filed immediately against the transportation company by the
consignee.
Factory warranty (shipped with unit) does not apply to units
improperly installed or improperly operated.
Failure to adhere to the guidelines on this
⚠WARNING
page can result in severe personal injury,
death, or substantial property damage.
⚠WARNING DO NOT install units in rooms or
environments that contain corrosive
contaminants (see Table 1A on page 4). Failure to comply
could result in severe personal injury, death, or substantial
property damage.
Boiler service and maintenance –
• To avoid electric shock, disconnect electrical supply
before performing maintenance.
• To avoid severe burns, allow boiler to cool before
performing maintenance.
User's Information Manual
Boiler operation –
• Do not block flow of combustion or ventilation air to
the boiler. This boiler is equipped with a control which
will automatically shut down the boiler should air or
vent be blocked.
accessible and removable, remove it. The boiler should
attempt to restart. If blockage is not obvious or cannot
be removed, have the boiler and system checked by a
qualified service technician.
• Should overheating occur or gas supply fail to shut off,
do not turn off or disconnect electrical supply to the
circulator. Instead, shut off the gas supply at a location
external to the appliance.
• Do not use this boiler if any part has been under water.
The possible damage to a flooded appliance can be
extensive and present numerous safety hazards. Any
appliance that has been under water must be replaced.
• This product burns gas to produce heat. The appliance
must be properly installed, operated, and maintained to
avoid exposure to appreciable levels of carbon monoxide
and the installer is required to confirm that at least one
carbon monoxide alarm is installed in the living space
before the appliance is put into operation. It is important
for the carbon monoxide alarms to be installed,
maintained, and replaced following the alarm
manufacturer's instructions and applicable local codes.
Boiler water –
• Thoroughly flush the system (without boiler
connected) to remove sediment. The high-efficiency
heat exchanger can be damaged by build-up or
corrosion due to sediment.
• Do not use petroleum-based cleaning or sealing
compounds in the boiler system. Gaskets and seals in
the system may be damaged.
substantial property damage.
• Do not use "homemade cures" or "boiler patent
medicines". Serious damage to the boiler, personnel,
and/or property may result.
• Continual fresh make-up water will reduce boiler life.
Mineral buildup in the heat exchanger reduces heat
transfer, overheats the stainless steel heat exchanger,
and causes failure. Addition of oxygen carried in by
makeup water can cause internal corrosion. Leaks in
boiler or piping must be repaired at once to prevent
makeup water.
Freeze protection fluids –
• NEVER use automotive antifreeze. Use only inhibited
propylene glycol solutions, which are specifically
formulated for hydronic systems.
toxic and can attack gaskets and seals used in hydronic
systems.
If vent or air blockage is easily
This can result in
Ethylene glycol is
3