Regarding the Lamp (Continued)
Removing and Installing the
Lamp Unit
Warning!
Do not remove the lamp unit from the
projector right after use. The lamp and parts
around the lamp will be very hot and may
cause burns or injury.
Info
Do not touch the glass surface of the lamp
unit or the inside of the projector.
To avoid injury to yourself and damage to the
lamp, make sure you carefully follow the
steps below.
Do not loosen other screws except for the
lamp unit cover and lamp unit.
1
1
Press STANDBY/ON on the
projector or STANDBY on the
remote control to put the
projector into standby mode.
Wait until the cooling fan stops.
2
2
Disconnect the power cord.
Unplug the power cord from the AC
socket.
Leave the lamp until it has fully cooled
down (about 1 hour).
3
3
Remove the lamp unit cover.
Turn over the projector and place it on a
board or other raised surface on a table so
as not to allow the lens to come in contact
with the table. Loosen the user service
screw (1) that secures the lamp unit
cover. Remove the lamp unit cover (2).