Summary of Contents for Sinclair ASP-12BI

  • Page 1 Installation Manual | - - Ver. 06 03 2021 CONSOLE SERIES INDOOR UNITS ASP-09BI ASP-12BI ASP-18BI...
  • Page 2 I M P O R T A N T N O T E : Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.
  • Page 3: Table Of Contents

    Contents OPERATION INSTRUCTIONS The Refrigerant ............................1 Precautions ..............................2 1. Part names and their functions .......................7 2. How to use the remote control to operate the unit ................. 8 3. Maintenance ............................13 4. Operating guide ........................... 16 5.
  • Page 4 Explanation of Symbols Indicates a hazardous situation that, if not avoided, will DANGER result in death or serious injury. Indicates a hazardous situation that, if not avoided, could WARNING result in death or serious injury. Indicates a hazardous situation that, if not avoided, may CAUTION result in minor or moderate injury.
  • Page 5: Operation Instructions

    Appliance filled with flammable gas R32. Before use the appliance, read the owner’s manual first. Before install the appliance, read the installation manual first. Before repair the appliance, read the service manual first. The Refrigerant OPERATION INSTRUCTIONS To realize the function of the air conditioner unit, a special refrigerant circulates in the system.
  • Page 6: Precautions

    Precautions OPERATION INSTRUCTIONS WARNING Operation and Maintenance This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 7 Precautions OPERATION INSTRUCTIONS WARNING Maintenance must be performed by qualified professionals. Otherwise, it may cause personal injury or damage. Do not repair air conditioner by yourself. It may cause electric shock or damage. Please contact dealer when you need to repair air conditioner. Do not extend fingers or objects into air inlet or air outlet.
  • Page 8 Precautions OPERATION INSTRUCTIONS WARNING Attachment Installation must be performed by qualified professionals. Otherwise, it may cause personal injury or damage. Must follow the electric safety regulations when installing the unit. According to the local safety regulations, use qualified power supply circuit and circuit break. Do install the circuit break.
  • Page 9 Precautions OPERATION INSTRUCTIONS WARNING Do not put through the power before finishing installation. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
  • Page 10 Precautions OPERATION INSTRUCTIONS WARNING For the air conditioner with plug, the plug should be reachable after finishing installation. For the air conditioner without plug, an circuit break must be installed in the line. If you need to relocate the air conditioner to another place, only the qualified person can perform the work.
  • Page 11: Part Names And Their Functions

    Part names and their functions OPERATION INSTRUCTIONS INDOOR UNIT CAUTION Before opening the front panel, be sure to Air outlet selection switch stop the operation and turn the breaker OFF. Do not touch the metal parts on the inside This setting blows air from •...
  • Page 12: How To Use The Remote Control To Operate The Unit

    How to use the remote control to operate the unit OPERATION INSTRUCTIONS Remote Controller Description ON/OFF Press it to start or stop operation. : Press it to decrease temperature setting. : Press it to increase temperature setting. MODE Press it to select operation mode (AUTO/COOL/DRY/FAN/HEAT).
  • Page 13 How to use the remote control to operate the unit OPERATION INSTRUCTIONS Remote Controller Description Note: ● This is a general use remote controller, it could be used for the air conditioners with multifunction; For some function, which the model doesn't have, if press the corresponding button on the remote controller that the unit will keep the original running status.
  • Page 14 How to use the remote control to operate the unit OPERATION INSTRUCTIONS SWING: Press this button to set up &down swing angle, which circularly changes as below: This remote controller is universal . If any command is sent out, the unit will carry out the command as indicates the guide louver swings as: I FEEL:...
  • Page 15 How to use the remote control to operate the unit OPERATION INSTRUCTIONS TEMP: Press this button, could select displaying the indoor setting temperature or indoor ambient temperature.When the indoor unit firstly power on it will display the setting temperature, if the temperature's displaying status is changed from other status to" ",displays the ambient temperature, 5s later or within 5s, it receives other remote control signal that will return to display the setting temperature.
  • Page 16 How to use the remote control to operate the unit OPERATION INSTRUCTIONS Combination of "MODE " and "-" buttons : About switch between Fahrenheit and centigrade " " " - " At unit OFF, press MODE buttons simultaneously to switch between ℉...
  • Page 17: Maintenance

    Maintenance OPERATION INSTRUCTIONS Before inspection and maintenance of the unit. PLEASE set power switch to “OFF” to cut off the power supply. Units ● Indoor unit, Outdoor unit and Remote controller 1. Wipe them with dry soft cloth. ● Front panel Open the front panel.
  • Page 18 Maintenance OPERATION INSTRUCTIONS Titanium Apatite Photocatalytic 4. Clean or replace each filter. Air-Purifying Filter See figure. Air filter 5. Set the air filter and Titanium Apatite Photocatalytic Air-Purifying Filter as they were and close the front panel. • Operation without air filters may result in troubles as dust will accumulate inside the indoor unit.
  • Page 19 Maintenance OPERATION INSTRUCTIONS Check Check that the base, stand and other fittings of the outdoor unit are not decayed or corroded. Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit. Check that the drain comes smoothly out of the drain hose during COOL or DRY operation. •...
  • Page 20: Operating Guide

    Operating guide OPERATION INSTRUCTIONS Working principle and special functions for cooling Principle: Air conditioner absorbs heat in the room and transmit to outdoor and discharged, so that indoor ambient temperature decreased, its cooling capacity will increase or decrease by outdoor ambient temperature. Anti-freezing function: If the unit is running in COOL mode and in low temperature, there will be frost formed on the heat exchanger, when indoor heat exchanger temperature decreased below 0...
  • Page 21 Operating guide OPERATION INSTRUCTIONS To distribute cool air through out the roon, The temperature should not be set lower than adjust air flow direction as shown by the what you need. This would result to increase arrows (see picture) to diffuse cool air. energy cost.
  • Page 22: Precautions

    Precautions OPERATION INSTRUCTIONS Check electrical system(voltage and frequency). Turn off the airconditioner if ,while running, Use the proper power supply indicated on the electricity interference occurs.If the unit is not unit to operate the airconditioner and only fuses to be used for a long time,cut off the power with specified capacity.Do not use pieces of wire supply main switch.
  • Page 23: Checking Before Contact The Service Man

    Checking before contact the service man OPERATION INSTRUCTIONS Check the following before contact the service man.You may find the solution to your problems. After checking,if it still does not operate, please contact your local dealer. PROBLEM CAUSES Check if eletrical wire is damaged & check if breaker NO operation switch is still on.
  • Page 24: Installation Instructions

    Installation of indoor unit INSTALLATION INSTRUCTIONS SELECTION OF INSTALLATION LOCATION. Exposed Half conceated Concealed Such a place where cool air can be distributed ● Mounting plate throughout the room. Such a place where condensation water is easily ● drained out. Such a place that can handle the weight of indoor unit.
  • Page 25 Installation of indoor unit INSTALLATION INSTRUCTIONS Refrigerant piping 1)Drill a hole ( 55mm in diameter ) in the spot indicated by the symbol in the illustration as below . 2)The location of the hole is different depending on which side of the pipe is taken out . 3)For piping ,see Connecting the refrigerant pipe ,under Indoor Unit Installation(1).
  • Page 26 Installation of indoor unit INSTALLATION INSTRUCTIONS Boring a wal l hole and installing wal l embedded pipe For walls containing metal frame or metal board ,be sure to use a wall embedded Inside Outside pipe and wall cover in the feed-through hole to prevent water leakage. Wall embedded pipe (field supply) Be sure to caulk the gaps around the pipes with caulking material to prevent...
  • Page 27 Installation of indoor unit INSTALLATION INSTRUCTIONS Installing indoor unit 3 tabs 1.Preparation Casing Open the front panel, remove the 4 screws and dis- mount the front grille while pulling it forward. Front grille Follow the arrows to disengage the clasps on the front case to remove it.
  • Page 28 Installation of indoor unit INSTALLATION INSTRUCTIONS The mounting plate should be installed on a wall which can support the weight of the indoor unit. 1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the boring points on the wall.
  • Page 29 Installation of indoor unit INSTALLATION INSTRUCTIONS Connecting the refrigerant pipe 1) Use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and gas leaks. Open-end wrench (fixed) Coat here with refrigeration oil Flare nut Wrench Connection pipe Indoor unit tubing 2) Align the centres of both flares and tighten the flares and tighten the flare nuts 3 or 4 turns by hand.
  • Page 30 Installation of indoor unit INSTALLATION INSTRUCTIONS Checking for gas leakage 1)Check for leakage of gas after air purging 2)See the sections on air purges and gas leak checks in the installation manual for the outdoor unit. Check for leakage here Apply soapy water and ch- eck carefully for leaking gas.
  • Page 31 Installation of indoor unit INSTALLATION INSTRUCTIONS Wiring With a Multi indoor unit, install as described in the installation manual supplied with the Multi outdoor unit. Live the sensor securing plate, remove the front metal plate cover, and connect the branch wiring to the terminal block. 1)Strip wire ends (15mm) 2)Mach wire colours with terminal numbers on indoor and outdoor unit’s terminal blocks and firmly screw wires to the corresponding terminals.
  • Page 32: Pipe Preparation

    Pipe preparation INSTALLATION INSTRUCTIONS Wrong Cutting Tool Right PIPE & ELECTRICAL WIRE CUTTING Sloped Cut Rough Cut Use cutting tools easily found in the market. Measure precisely both outer & inner pipe. Provide a little bit longer pipe than the measurement. Wire must be 1.5 m.
  • Page 33: Refrigerant Piping Work

    Refrigerant piping work INSTALLATION INSTRUCTIONS 9.1 Select copper pipes for gas and liquid as informed in specific table(see the pipe table below) 9.2 For dust and moisture protection, before assembly of the pipe and its insulation,both end of the pipe must be covered. 9.3 Avoid pipe bending as much as possible.If it is necessary, the bending radius must be more than 3cm.
  • Page 34: Routine Check After Installation

    Routine check after installation INSTALLATION INSTRUCTIONS Check after installation Items to be checked Possible malfunction Situation Has it been fixed firmly? The unit may drop,shake or emit noise. Have you done the refrigerant leakage test? It may cause insufficient refrigerating capacity. Is heat insulation sufficient? It may cause condensation and dripping.
  • Page 35: Configuration Of Connection Pipe

    INSTALLATION INSTRUCTIONS 1. Standard length of connection pipe ● 5m, 7.5m, 8m. 2.Min. length of connection pipe is 3m. 3.Max. length of connection pipe. Sheet 1 Max length of connection pipe Unit: m Max length Max length Cooling Cooling of connec- of connec- capacity capacity...
  • Page 36 INSTALLATION INSTRUCTIONS Sheet 2. Additional refrigerant charging amount for R32 Diameter of connection pipe mm Indoor unit throttle Outdoor unit throttle Cooling only, cooling and Cooling only Liquid pipe Gas pipe cooling and heating heating (g / m) (g / m) (g / m) Ф6 Ф9.5 or Ф12...
  • Page 37: Safety Operation Of Flammable Refrigerant

    Safety operation of flammable refrigerant INSTALLATION INSTRUCTIONS Qualification requirement for installation and maintenance man All the work men who are engaging in the refrigeration system should bear the valid certification awarded by the authoritative organization and the qualification for dealing with the refrigeration system recognized by this industry. If it needs other technician to maintain and repair the appliance, they should be supervised by the person who bears the qualification for using the flammable refrigerant.
  • Page 38 Safety operation of flammable refrigerant INSTALLATION INSTRUCTIONS a. Shut down the unit and cut power supply b. Eliminate the refrigerant c. Vacuuming d. Clean it with N2 gas e. Cutting or welding f. Carry back to the service spot for welding The refrigerant should be recycled into the specialized storage tank.
  • Page 39 United Kingdom www.sinclair-world.com This product was manufactured in China (Made in China). R E P R E S E N T A T I V E SINCLAIR Global Group s.r.o. Purkynova 45 612 00 Brno Czech Republic T E C H N I C A L S U P P O R T SINCLAIR Global Group s.r.o.