Summary of Contents for Sinclair MULTI SYSTEM SERIES

  • Page 1 USER'S MANUAL MULTI SYSTEM SERIES OUTDOOR UNITS MS-E18AI, MS-E24AI, MS-E28AI...
  • Page 2 “Original instructions”  ...
  • Page 3: Table Of Contents

    In line with the company’s policy of continual product improvement, the aesthetic and dimensional characteristics, technical data and accessories of this appliance may be changed without notice. GENERAL INFORMATION CONTENTS Conformity And Range The Instructions Before Use Name of Parts Technical Data Outdoor Unit Working Temperature Range Electrical Connections...
  • Page 4: The Instructions Before Use

    THE INSTRUCTIONS BEFORE USE GENERAL INFORMATION WARNING When having a burning smell or The power supply must adopt the Never cut off or damage power ★ ★ ★ smoke,please turn off the power special circuit that with air switch cables and control wires. If the supply and contact with the ser- protection and assure it has enou- power cable and signal control...
  • Page 5: Name Of Parts

    NAME OF PARTS GENERAL INFORMATION MS-E18AI Warning Be sure to cut off the power supply before cleaning the air conditioner; otherwise electric shock might happen. Wetting of air conditioner may cause the risk of electric shock. Make sure not to wash your air conditioner in any case.
  • Page 6: Technical Data

    TECHNICAL DATA GENERAL INFORMATION MODE MS-E18AI Electrical data Electricity supply 220-240V~,50Hz Fuse or air switch Minimum power cord section Size and clearance TECHNICAL DATA GENERAL INFORMATION MODE MS-E24AI, MS-E28AI Electrical data Electricity supply 220-240V~,50Hz Fuse or air switch Minimum power cord section Size and clearance OUTDOOR UNIT WORKING TEMPERATURE RANGE GENERAL INFORMATION...
  • Page 7: Electrical Connections

    ELECTRICAL CONNECTIONS INSTALLER MS-E18AI MS-E18AI 1. Remove the handle at the right side plate of the outdoor unit (one screw). Handle 2. Remove the cable clamp, connect the power connection cable with the terminal at the row of connection and fix the connection.
  • Page 8 ELECTRICAL CONNECTIONS INSTALLER MS-E24AI: 1. Remove the handle at the right side plate of the An all-pole disconnection switch having a contact outdoor unit (one screw). separation of at least 3mm in all pole should be connected in fixed wiring. 3.
  • Page 9 ELECTRICAL CONNECTIONS INSTALLER MS-E28AI 1. Remove the handle at the right side plate of the An all-pole disconnection switch having a contact outdoor unit (one screw). separation of at least 3mm in all pole should be connected in fixed wiring. 3.
  • Page 10: Installing The Outdoor Unit

    INSTALLING THE OUTDOOR UNIT INSTALLER Location Install the drain fitting and the drain hose (for model with heat pump only) Use bolts to secure the unit to a flat, solid floor. Condensation is produced and flows from the out- When mounting the unit on a wall or the roof, make door unit when the appliance is operating in the sure the support is firmly secured so that it cannot heating mode.
  • Page 11: Maintenance

    MAINTENANCE INSTALLER Use suitable instruments for the refrigerant R410A. Do not use any other refrigerant than R410A. ● Do not use mineral oils to clean the unit. INSTALLATION DIMENSION DIAGRAM INSTALLER The installation must be done by trained and qualified service personnel with reliability according to this manual.
  • Page 12: Check After Installation

    CHECK AFTER INSTALLATION INSTALLER Check Items Problems Owing to Improper Installation Is the installation reliable? The unit may drop, vibrate or make noises May cause unsatisfactory cooling (heating) Has the gas leakage been checked? effect Is the thermal insulation of the unit May cause condensation and water dropping sufficient? Is the drainage smooth?