Honeywell TrueSTEAM HM612A1000/U Installation Manual page 31

Steam humidifier
Table of Contents

Advertisement

1
2
3
On
Off
1
2
3
On
Off
1
2
3
On
Off
1
2
3
On
Off
Steam Humidifier System 69-2285—11
4
5
6
M29610
4
5
6
M29611
4
5
6
M29612
4
5
6
M29613
DIPS 3, 4, and 5 are used to configure the
humidifier operation for your unique
application.
DIP 3: Used to enable wireless operation.
If DOWN (default), wireless terminal is disabled.
If UP, wireless terminal is enabled.
DIP 4: Used to configure power monitoring.
If DOWN (default), steam humidifier looks for R
input before allowing humidity.
If UP, steam humidifier does not look for R Input
before allowing humidity. Power is still allowed
to pass through if R is wired. See "Make Power
Monitoring Decision" on page"STEP ONE: Make
Power Monitoring Decision" on page 30.
DIP 5: (optional) Used to prevent humidification when
air is not moving throughout the duct. Requires a
remote air flow sensor.
If DOWN (default), steam humidifier does not look
for air movement through an air proving device.
If UP, steam humidifier looks for C connection
before allowing humidity. Wire an air proving device
between steam humidifier C and System C. See
"Make Add-On Air Proving Decision" on page 32.
Note: Setting DIP 5 up requires DIP 4 to be down. If
DIP 4 is up, DIP 5 position will not be used.
DIP 6: Not used at this time.