3-1. OPERATING RANGE
(1) POWER SUPPLY
Rated voltage
Indoor unit
(2) OPERATION
Mode
Condition
Standard temperature
Maximum temperature
Cooling
Minimum temperature
Maximum humidity
Standard temperature
Heating
Maximum temperature
Minimum temperature
3-2. OUTLET AIR SPEED AND COVERAGE
Model
Mode
HEAT
MSZ-JP09WA
COOL
HEAT
MSZ-JP12WA
COOL
OBH820A
Guaranteed voltage (V)
115 V
Min. 103
1 phase
60 Hz
DB
80
90
67
70
80
70
Airflow
Function
(CFM)
Dry
406
Dry
399
Wet
364
Dry
406
Dry
399
Wet
364
115
Max. 127
Intake air temperature (°F)
Indoor
WB
67
73
57
78%
60
67
60
● The air coverage is the figure up to the
Air speed
Coverage
(ft./s.)
(ft.)
20.6
29.5
20.2
29.0
18.4
26.5
20.6
29.5
20.2
29.0
18.4
26.5
5
Outdoor
DB
95
115
14
47
75
-4
position where the air speed is 1 ft./s.,
when air is blown out horizontally from
the unit properly at the High speed
position.
The coverage should be used only as a
general guideline since it varies accord-
ing to the size of the room and furniture
arranged inside the room.
WB
43
65
-5