Installation Instructions PXDR10 Drain Kit
NOTE: Determine whether drain will be located within the wall, on the indoor side, or will drain to the exterior of the building.
Follow appropriate instructions below depending on your particular type of installation.
Internal Drain (optional for new construction)
NOTE: If installing an internal drain, you MUST install a drain kit
on the wall sleeve before the wall sleeve is installed.
1.
Refer to Figure 3 below and locate the drain within the
"Primary" area for best drainage. Maintain at least a ½"
clearance from the embossed area.
2.
Using the mounting plate with the ½" hole as a template,
mark and drill two, 3/16" mounting holes and a ½" drain
hole.
3.
Remove the backing from the gasket and mount it on the
fl at side of the mounting plate. (See Figure 4.) Insert the
drain tube through the hole in the gasket and mounting
plate so the tube fl ange will be against the wall sleeve.
4.
Position the assembly beneath the drilled holes and secure
it with #10-24 x ½" machine screws and lock nuts provided.
Seal the tops of the screws with silicone caulking.
5.
Use ½" I.D. copper tube, PVC pipe, or vinyl hose (obtained
locally) to connect the internal drain tube to the drain
system in the building.
6.
Referring to Detail A on page 9, locate and assemble the
(2) two cover plates and gaskets over the drain holes at
the rear of the wall sleeve. Attach them with the #10 sheet
metal screws provided. Make certain that the four overfl ow
slots at the rear of the wall sleeve are not blocked (See
drawing of the back of the sleeve on page 9).
7.
If a deep wall extension (PXWE) is used, after installing
the fi eld supplied fl ashing, caulk as required. Be sure to
caulk around the fl ashing and the wall sleeve where the
hole was drilled for the drain tube.
8
920-087-06
Figure 3
Drain Kit Location and Installation
Secondary area
Primary area - no foam insulation
If the drain must be located in the
secondary area, the foam insulation
must be cut away and removed to
allow access to the drain.
Wall sleeve
Gasket
Mounting plate
Drain tube
Screw
Nut
3"
7.6 cm