Zenith XBR411 Manual page 120

Hide thumbs Also See for XBR411:
Table of Contents

Advertisement

5. Optical Power Setting
When replacing Travers ass'y including Pick-up or Loader PCB, Optical Power Setting should be performed for Pick-up
and Loading PCB's matching.
➀ DVD LD optocal Power Setting
• Select DVD and Setup
• Push
. (Read Power On. Strong Red light can be seen.)
• Measure optical power.
• Write measurement value in Read Power.
• Push
. (Write power On.) (Caution) Light is very strong. Never look at the light directly.
• Measure optical power and push
• Write measurement value in Read Power.
• Push
. (Measurement value is inputted to EEPROM)
➁ DVD LD optocal Power Setting
• Select CD and Setup
• Push
. (Read Power On. Weak Red light can be seen.)
• Measure optical power.
• Write measurement value in Read Power.
• Push
. (Write power On. Weak Red light can be seen.)
• Measure optical power and push
• Write measurement value in Read Power.
• Push
. (Measurement value is inputted to EEPROM)
. (LCD off)
. (LCD off)
3-143

Advertisement

Table of Contents
loading

Table of Contents