Bond in accordance with national and
local codes. Open bonding lugs are
located at the top of the junction box.
120/240 VAC Source
N
L1
120 V
120 V
240 V
* Equipment Ground
Neutral Bus
(In Breaker Box)

3. Make Electrical Connections

NOTE: The product model number is printed on a label on the blower side of the bath. This label also
identifies the electrical rating of the product. All baths come equipped with a wiring junction box and
are designed to operate between 220 V and 240 V at either 50 Hz or 60 Hz.
WARNING: Risk of electrical shock. Make sure the power has been disconnected before
performing the following procedures.
WARNING: Risk of electrical shock. Connect the blower to a properly grounded Ground-Fault
Circuit-Interrupter (GFCI) or Residual Current Device (RCD). This will provide additional
protection against line-to-ground shock hazard. A 220-240 V, 20 A, 50/60 Hz dedicated circuit is
required.
IMPORTANT! The load neutral is not used. There should be no connection to the load neutral terminal
on the Ground-Fault Circuit-Interrupter (GFCI) breaker. The green wire with the yellow stripe is the
equipment ground and needs to be connected to the neutral bus in the main circuit breaker box.
NOTE: The wiring harness includes an antenna for the optional remote control. Do not alter or damage
this antenna during installation.
1204120-2-A
Control
L2
Breaker Box
Typical Two-Pole
Circuit Breaker
with GFCI
No Connection
(Load Neutral)
* Line Neutral
(White
Curly Wire)
Field Wiring
(From Junction Box
to GFCI Breaker)
Check Valve
Blower Motor Cord
Control
Power Supply
External Power
Control Power
Junction Box
Wire
*L2
Connector
240 V
*L1
White
(Neutral)
Blue (L1)
8
Typical Wiring Connection
* Connections to be Made
at the Circuit Breaker
Ground
Ground
(Green)
(Green with
Yellow Stripes)
Black (L1)
Brown (L2)
Electrician to provide
suitable strain relief.
From Heated
Surface
From Control
Kohler Co.