Installation Instructions - Kohler K-1947-XHGL-33 Installation And Care Manual

Bath with airjets
Table of Contents

Advertisement

Available languages

Available languages

Installation Instructions

WARNING: When using electrical products, basic precautions should always be followed,
including the following:
DANGER: Risk of electric shock. Connect only to a circuit protected by a Ground-Fault
Circuit-Interrupter (GFCI)*.
Building materials and wiring should be routed away from the whirlpool pump, blower motor, and other
heat-producing components of the unit.
Install to permit access for servicing.
A pressure wire connector marked "Earth/Ground" is provided within the wiring compartment. To reduce
the risk of electric shock, connect this connector to the grounding terminal of your electric service or supply
panel with copper wire equivalent in size to the circuit conductor supplying this equipment.
A pressure wire connector is provided on the exterior of the pump or control within this unit to permit
connection of a bonding conductor between this unit and all the other exposed metal in the vicinity, as
needed to comply with local requirements.
Grounding is required. The unit should be installed by a qualified service representative, and grounded.
WARNING: Risk of injury or property damage. Please read all instructions thoroughly before
beginning installation, including the following requirements.
WARNING: Risk of electric shock. A qualified electrician should make all electrical connections.
WARNING: Risk of electric shock. Disconnect power before servicing.
NOTICE: Follow all local plumbing and electrical codes. In Canada, install this unit in accordance with
the Canadian Electrical Code, Part 1.
*Outside North America, this device may be known as a Residual Current Device (RCD).
Product Information
Electrical Requirements
The installation must have Class A Ground-Fault Circuit-Interrupters (GFCI's). The GFCI's protect against
line-to-ground shock hazards. Use 120 V, 15 A, 60 Hz dedicated services for the pump motor and blower.
"H" models require a separate 120 V, 15 A, 60 Hz dedicated service for the heater.
If a power supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard. The heater supply cord cannot be replaced. If the heater supply
cord is damaged the heater must be replaced.
Product Notices
WARNING: Unauthorized modification may cause unsafe operation and poor performance of
the bath. Do not relocate the whirlpool pump motor or blower motor, or make other modifications
to the bath system, as this could adversely affect the performance and safe operation of the product.
Kohler Co. shall not be liable under its warranty or otherwise for personal injury or damage caused
by any such unauthorized modification.
NOTICE: Keep the area around the blower clean and free of debris. Ensure that the area around the
blower is free of sawdust, insulation, dirt, and other small loose debris. Such material can block the blower
air ducts and reduce the air flow through the blower.
NOTICE: This product contains an automatic water purge mode that turns the blower on for 2 minutes
about 30 minutes after the unit is turned off and drained.