Safety Considerations - Carrier F80VTL Installation, Start-Up, Operating And Service And Maintenance Instructions

80% afue, variable 25-speed, ecm motor, two-stage, 4-way multipoise, non-condensing gas furnace
Table of Contents

Advertisement

F80VTL & G80VTL (Major Series B): Installation, Start-up, Operating and Service and Maintenance Instructions
FURNACE SIZE
0451412
14-3/16 (360)
0701716
17-1/2 (445)
0902120
1102122
WARNING
!
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in personal injury and/or
death.
Carbon Monoxide (CO) is a colorless, odorless, and tasteless poisonous
gas that can be fatal when inhaled. Follow all installation, maintenance,
and service instructions. See additional information below regarding
the installation of a CO Alarm.
Most states in the USA and jurisdictions in Canada have laws that
require the use of Carbon Monoxide (CO) alarms with fuel burning
products. Examples of fuel burning products are furnaces, boilers, space
heaters, generators, water heaters, stoves/ranges, clothes dryers,
fireplaces, incinerators, automobiles, and other internal combustion
engines. Even if there are no laws in your jurisdiction requiring a CO
Alarm, it's highly recommended that whenever any fuel burning product
is used in or around the home or business that the dwelling be equipped
with a CO Alarm(s). The Consumer Product Safety Commission
recommends the use of CO Alarm(s). The CO Alarm(s) must be
installed, operated, and maintained according to the CO Alarm
manufacturer's instructions. For more information about Carbon
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Fig. 1 – Dimensional Drawing
A
B
CABINET
OUTLET
WIDTH
WIDTH
12-9/16 (319)
15-7/8 (403)
21 (533)
19-3/8 (492)
21 (533)
19-3/8 (492)
Table 1 – Dimensions
C
D
TOP AND
BOTTOM
BOTTOM FLUE
INLET WIDTH
COLLAR
9-5/16 (237)
12-11/16 (322)
11-9/16 (294)
16 (406)
13-5/16 (338)
19-1/2 (495)
13-5/16 (338)
19-1/2 (495)
Monoxide, local laws, or to purchase a CO Alarm online, please visit the
following website. https://www.kidde.com.

SAFETY CONSIDERATIONS

FIRE, INJURY, OR DEATH HAZARD
Failure to follow this warning could result in property damage, personal
injury, or death.
This furnace was manufactured to operate with natural gas. When fuel
supply is Liquid Propane (LP), this furnace must be converted with a
factory approved LP conversion kit. See furnace rating plate for
approved conversion kit.
2
VENT
SHIP WT.
CONNECTION
LB (KG)
SIZE
4 (102)
114 (51.7)
4 (102)
134 (60.8)
4 (102)
149 (67.6)
4 (102)
155 (70.3)
WARNING
!
A190084
ACCESSORY
FILTER
MEDIA
CABINET SIZE
16 (406)
16 (406)
20 (506)
20 (506)

Advertisement

Table of Contents
loading

This manual is also suitable for:

G80vtl

Table of Contents