Stacked Dryers Inside... Dimensions... Before You Start... Installing the Dryer... Installer Checklist... Back Cover Para bajar una copia de estas instrucciones en español, visite www.speedqueen.com. Keep these instructions for future reference. (If this machine changes ownership, this manual must accompany machine.)
Page 2
FOR YOUR SAFETY, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death. • Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Dimensions 23.5 in. (59.7 cm) (20.3 cm) 5.25 in. (13.3 cm) 28 in. (71.1 cm) 0.4 in. (1.1 cm) * With leveling legs turned into base. 23.5 in. (59.7 cm) (20.3 cm) 5.25 in. (13.3 cm) 28 in. (71.1 cm) 0.4 in.
No other fuel burning appliance should be installed in the same closet with the dryer. The dryer must not be installed or stored in an area where it will be exposed to water and/or weather. The dryers needs sufficient clearance and an adequate air supply for proper operation and ventilation, and for easier installation and servicing.
Page 6
Place the dryer in position, and adjust the legs until the dryer is level from side to side and front to back. The dryer must not rock. Dryer Base Level Leveling Leg Figure 3 IMPORTANT: In mobile home installations, gas dryers MUST be permanently attached to the floor at the time of installation.
Page 8
NOTE: When connecting to a gas line, an equipment shut-off valve must be installed within 6 feet (1.8 m) of the dryer. An 1/8 in. NPT pipe plug must be installed as shown for checking inlet pressure. Refer to Figure 5.
Page 9
208 Volt. Part No. • If branch circuit to dryer is 15 feet (4.57 m) or 1.32 58755 less in length, No. 10 AWG wire (copper wire only), or as required by local codes.
Page 10
NOTE: The power cord is NOT supplied with the electric dryer. Type of power cord and gauge of wire must conform to local codes and instructions. The method of wiring the dryer is optional and subject to local code requirements.
Page 11
NOTE: Four-wire cord is required for mobile homes or where codes do not permit grounding through neutral. D286I 1. Disconnect power to dryer. 2. Remove access cover from rear of dryer. 240 ± 12 V.A.C. V.A.C. DRY2016N Typical Four-Wire Receptacle Power Cord –...
Page 12
8. Secure the strain relief to the power cord, or wires, where they enter the dryer cabinet. 9. Check the continuity of the ground connection before plugging the cord into an outlet. Use an...
Page 13
DRY2058N • Do not use an adapter. • Do not use an extension cord. • Do not operate both a washer and gas dryer on the same circuit. Use separetely fused 15 amp circuits. The dryer is designed to be operated on a separate...
Page 14
Do not modify the plug provided with the dryer – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
Page 15
To view the burner flame, remove the lower front panel of the dryer. Close the loading door, start the dryer in a heat setting (refer to the Operating Instructions supplied with the dryer); the dryer will start, the igniter will glow red and the main burner will ignite.
(Refer to the manual for more detailed information) • Position and Level the Dryer. LEVEL D255I D255I CHECK • Connect Dryer Exhaust System. CHECK GAS ONLY • Connect Gas Supply Pipe Hoses. • Check for Gas Leaks. CHECK ELECTRIC ONLY •...