Figure 176. Status LED indicators
Table 102. Status LED indicators and descriptions
Icon
Description
Drive indicator
Temperature
indicator
Electrical
indicator
Memory indicator
PCIe indicator
Condition
The indicator turns solid amber if
there is a drive error.
The indicator turns solid amber if
the system experiences a thermal
error (for example, the ambient
temperature is out of range or
there is a fan failure).
The indicator turns solid amber
if
the
system
experiences
electrical
error
(for
voltage out of range, or a failed
power
supply
unit
(PSU)
voltage regulator).
The indicator turns solid amber if a
memory error occurs.
The indicator turns solid amber if a
PCIe card experiences an error.
Corrective action
● Check the System Event Log to determine if the
drive has an error.
● Run the appropriate Online Diagnostics test.
Restart
the
diagnostics (ePSA).
● If the drives are configured in a RAID array,
restart the system, and enter the host adapter
configuration utility program.
Ensure that none of the following conditions exist:
● A cooling fan has been removed or has failed.
● System cover, air shrouds, or back filler bracket
has been removed.
● Ambient temperature is too high.
● External airflow is obstructed.
If the problem persists, see the
Check the System Event Log or system messages
for the specific issue. If it is due to a problem with
an
the PSU, check the LED on the PSU. Reseat the
example,
PSU.
If the problem persists, see the
or
Getting help
section.
Check the System Event Log or system messages
for the location of the failed memory. Reseat the
memory module.
If the problem persists, see the
Getting help
section.
Restart the system. Update any required drivers for
the PCIe card. Reinstall the card.
System diagnostics and indicator codes
system
and
run
embedded
Getting help
section.