Single stage, multi-speed ecm, non–condensing gas furnace input capacities: 45,000 thru 155,000 btuh
Hide thumbs Also See for R80ESL:
Table of Contents

Advertisement

R80ESN/R80ESL(Series A): Installation, Start–Up, Operating and Service and Maintenance Instructions
WARNING
!
CARBON MONOXIDE POISONING HAZARD
Failure to follow the steps outlined below for each appliance connected
to the venting system being placed into operation could result in carbon
monoxide poisoning or death.
The following steps shall be followed for each appliance connected to
the venting system being placed into operation, while all other
appliances connected to the venting system are not in operation:
1.Seal any unused openings in venting system.
2.Inspect the venting system for proper size and horizontal pitch, as
required in the current edition of National Fuel Gas Code, ANSI
Z223.1/NFPA 54 and these instructions. Determine that there is no
blockage or restriction, leakage, corrosion and other deficiencies,
which could cause an unsafe condition.
3.As far as practical, close all building doors and windows and all doors
between the space in which the appliance(s) connected to the venting
system are located and other spaces of the building.
4.Close fireplace dampers.
5.Turn on clothes dryers and any appliance not connected to the venting
system. Turn on any exhaust fans, such as range hoods and bathroom
exhausts, so they are operating at maximum speed. Do not operate a
summer exhaust fan.
6.Follow the lighting instructions. Place the appliance being inspected
into operation. Adjust the thermostat so appliance is operating
continuously.
7.Test for spillage from draft hood equipped appliances at the draft
hood relief opening after 5 minutes of main burner operation. Use the
flame of a match or candle.
8.If improper venting is observed during any of the above tests, the
venting system must be corrected in accordance with the current edition
of National Fuel Gas Code, ANSI Z223.1/NFPA 54.
9.After it has been determined that each appliance connected to the
venting system properly vents when tested as outlined above, return
doors, windows, exhaust fans, fireplace dampers and any other
gas-fired burning appliance to their previous conditions of use.
The Chimney Adapter Kit is listed alternative venting system for these
furnaces. See the kit instructions for complete details.
This furnace is permitted to be vented into a clay tile-lined masonry
chimney that is exposed to the outdoors below the roof line, provided:
1. Vent connector is Type-B double-wall, and
2. This furnace is common vented with at least 1 draft hood equipped
appliance, and
3. The combined appliance input rating is less than the maximum
capacity given in
Table
8, and
4. The input rating of each space heating appliance is greater than the
minimum input rating given in
Design Temperature. Chimneys having internal areas greater than
38 square inches require furnace input ratings greater than the input
ratings of these furnaces. See footnote at bottom of
5. The authority having jurisdiction approves.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Table 9
for the local 99% Winter
Table
9, and
Table 8 – Combined Appliance Maximum Input Rating

in Thousands of Btuh per Hour

VENT HEIGHT
FT. (M)
12
(7741)
6 (1.8)
74
8 (2.4)
80
10 (3.0)
84
15 (4.5)
NR
20 (6.0)
NR
30 (9.1)
NR
If all of these conditions cannot be met, an alternative venting design
shall be used, such as the listed chimney adapter kit with these furnaces,
which are listed for use with the kit, a listed chimney-lining system, or a
Type-B common vent.
Table 9 – Minimum Allowable Input Rating of Space-Heating
Appliance in Thousands of Btuh per Hour
VENT HEIGHT
FT (M)
Local 99% Winter Design
Temperature: 17 to 26°F (-8 to -3°C)
6 (1.8)
8 (2.4)
10 (3.0)
15 (4.6)
20 (6.1)
30 (9.1)
Local 99% Winter Design
Temperature: 5 to 16°F* (-15 to -9°C)
6 (1.8)
8 (2.4)
10 (3.0)
15 (4.6)
20 (6.1)
30 (9.1)
Local 99% Winter Design
Temperature: -10 to 4°F* (-23 to -16°C)
6 (1.8)
8 (2.4)
10 (3.0)
15 (4.6)
20 (6.1)
30 (9.1)
Local 99% Winter Design
Temperature: -11°F (-24°C) or lower
Not recommended for any vent configuration.
*The 99.6% heating db temperatures found in the 1997 or 2001 ASHRAE Fundamentals
Handbook, Climatic Design Information chapter, Table 1A (United States) or the 2005
ASHRAE Fundamentals handbook, Climatic Design Information chapter, and the CD-ROM
included with the 2005 ASHRAE Fundamentals Handbook.
21
INTERNAL AREA OF CHIMNEY
2
2
IN
(MM
)
19
28
(12258)
(18064)
119
178
130
193
138
207
152
233
NR
250
NR
NR
INTERNAL AREA OF CHIMNEY
2
2
IN
. (MM
)
12
19
28
(7741)
(12258)
(18064)
0
55
99
52
74
111
NR
90
125
NR
NR
167
NR
NR
212
NR
NR
NR
NR
78
121
NR
94
135
NR
111
149
NR
NR
193
NR
NR
NR
NR
NR
NR
NR
NR
145
NR
NR
159
NR
NR
175
NR
NR
NR
NR
NR
NR
NR
NR
NR
38
(24516)
257
279
299
334
368
404
38
(24516)
141
154
169
212
258
362
166
182
198
247
293
377
196
213
231
283
333
NR