International comfort products R80ESL Installation, Start-Up, Operating And Service And Maintenance Instructions page 17

Single stage, multi-speed ecm, non–condensing gas furnace input capacities: 45,000 thru 155,000 btuh
Hide thumbs Also See for R80ESL:
Table of Contents

Advertisement

R80ESN/R80ESL(Series A): Installation, Start–Up, Operating and Service and Maintenance Instructions
THREE-WIRE
HEATING-ONLY
BLOWER DOOR SWITCH
BLK
BLK
WHT
WHT
GND
AUXILIARY
115-V FIELD-
J-BOX
SUPPLIED
DISCONNECT
Fig. 24 – Heating and Cooling Application Wiring Diagram with 1-Stage Thermostat
\
WARNING
!
FIRE HAZARD
Failure to follow this warning could result in personal injury, death, or
property damage.
Do not connect aluminum wire between disconnect switch and furnace.
Use only copper wire (see
Fig.
Volts-
Unit Size
Hertz- Phase
0451412
115-60-1
0451712
115-60-1
0701412
115-60-1
0701712
115-60-1
0701716
115-60-1
0702116
115-60-1
0901714
115-60-1
0902116
115-60-1
0902120
115-60-1
0902420
115-60-1
1102120
115-60-1
1102420
115-60-1
1352420
115-60-1
* Permissible limits of the voltage range at which the unit operates satisfactorily.
# Unit ampacity = 125 percent of largest operating component's full load amps plus 100 percent of all other potential operating components' (EAC, humidifier, etc.) full load amps.
Time-delay type is recommended.
Length shown is as measured one way along wire path between unit and service panel for maximum 2 percent voltage drop.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
NOTE 2
W
C
FIVE WIRE
W
C
R
O
N
T
GND
R
G
O
COM
L
Y
24-V
TERMINAL
BLOCK
NOTES:
FURNACE
25).
Table 7 – Electrical Data
Operating Voltage* Range
Maximum
Minimum
127
104
127
104
127
104
127
104
127
104
127
104
127
104
127
104
127
104
127
104
127
104
127
104
127
104
THERMOSTAT
R
G
Y
TERMINALS
NOTE 1
CONDENSING
UNIT
TWO
WIRE
1.
Connect Y-terminal in furnace as shown for proper blower operation.
2.
Some thermostats require a "C" terminal connection as shown.
3.
If any of the original wire, as supplied, must be replaced, use
same type or equivalent wire.
ELECTRIC
DISCONNECT
SWITCH
Fig. 25 – Field-Supplied External Electrical Box on Furnace Casing
Unit
Minimum Wire
Ampacity#
Size AWG
7.8
14
10.3
14
7.8
14
7.8
14
14.3
14
13.3
14
11
14
11
14
16.9
12
13.5
14
17.4
12
14
14
14
14
17
FIELD 24-V WIRING
FIELD 115-, 208/230-, 460-V WIRING
FACTORY 24-V WIRING
FACTORY 115-V WIRING
FIELD-SUPPLIED
DISCONNECT
208/230- OR
460-V
THREE
PHASE
208/230-V
SINGLE
PHASE
GND
COPPER
WIRE ONLY
ALUMINUM
WIRE
Maximum Wire
Length
feet
47
14.3
36
47
14.3
47
14.3
25
7.6
27
8.2
33
10.1
33
10.1
34
10.4
27
8.2
33
10.1
26
7.9
26
7.9
A190079
A190279
Maximum
Fuse
or CKT
m
BKR Amps
15
11
15
15
15
15
15
15
15
20
15
20
15
15