Governor Lever Hole Position (8 mm)
E
D
C
B
A
Governor Lever
C
Hole 2
E
Hole 4
8 mm Governor Lever and Hole Position/RPM Chart
Gov. Lever
High Idle RPM
3900-4000
3825
3750-3800
3600-3700
3500-3550
3400-3450
3300-3350
3200-3250
3150
3100
3000
2900
3744*
3120*
*5% Regulation (others 10%)
24 690 30 Rev. G
A
B
Hole 1
D
Hole 3
Governor
Spring Color
Hole No.
Code
4
Red
3
Orange
3
Purple
3
Black
3
Red
2
Purple
2
Blue
1
Orange
3
Black
2
Clear
1
Red
1
Clear
2
Orange
1
Clear
KohlerEngines.com
Install Oil Sentry
(if equipped)
1. Apply pipe sealant with Tefl on
Thread Sealant or equivalent) to threads of Oil
Sentry
switch and install it into breather cover.
Torque to 4.5 N·m (40 in. lb.).
2. Connect wire lead (green) to Oil Sentry
Install Control Panel (if equipped)
1. Install panel to blower housing.
2. Connect throttle control cable or shaft.
3. Connect choke control cable to control bracket.
4. Connect Oil Sentry
Reassembly
(Loctite
PST
®
®
®
terminal.
indicator light wires.
592™