FUSE
4
Slot for the device fuse (30 A).
ADDITIONAL CABLE FUSE (NOT INCLUDED)
5
Install an extra fuse (not included) for the +12V power cable near the battery to secure the power
cable. The distance between the fuse and the battery should not exceed 30 cm. The fuse size must be
adapted to the cable cross-section of the installed power cable (see table below).
IMPORTANT: The fuse on the battery does not protect the amplifier, but the cable between the battery
and the amplifier against short circuits.
0 - 1,2
0 - 20
20 - 35
35 - 50
50 - 65
65 - 85
85 - 105
105 - 125
Recommended minimum cable cross-section to guarantee full amplifier performance:
Up to a length of 3 m: 10 mm
From a length of 3 m: 16 mm
6
POWER/PROTECT
If the LED lights up in blue, the amplifier is ready for operation. If the LED lights up in red, there is a
malfunction. Refer in this case to chapter TROUBLE SHOOTING on page 22.
CAUTION
Replace defective fuses only with a new one of the same type and with the same fuse rating.
1,2 - 2,1
2,1 - 3,1
2,5
4
4
4
6
10
6
10
10
10
10
16
16
16
20
16
16
20
20
20
20
Minimum cable cross-section in mm
2
2
Cable length in meters
3,1 - 4,0
4,0 - 4,9
6
6
10
16
16
16
20
20
20
35
35
35
35
35
ENGLISH
4,9 - 5,8
5,8 - 6,7
6,7 - 8,5
10
10
16
16
20
20
20
20
35
35
35
35
50
50
2
10
20
20
35
50
50
50
19