Setting The Heating Control Device; Operating The Menu; Settings In The Menu - Bosch Condens 4700iW User Instructions

Gas-fired condensing appliance
Hide thumbs Also See for Condens 4700iW:
Table of Contents

Advertisement

Operation
WARNING
Risk of scalding!
▶ This appliance is supplied with the CH control set at approximately
65 °C, a temperature that should be suitable for most installations.
When the boiler switches from CH to DHW, the temperature of the hot
water may briefly exceed the DHW set point if the CH temperature is
set higher than the DHW temperature. If the CH temperature is
changed to above 65 °C, it is advisable to fit a thermostatic mixing
valve (TMV) at the point of use (e.g. before the bath hot tap or
shower) to protect vulnerable people from scalding.
Setting preheat mode or eco mode
Press the ok key to switch between Eco/Preheat.
In Preheat mode, the hot water heat exchanger is kept pre-heated to
reduce the time taken to deliver hot water at the tap.
Eco mode is an energy saving feature which disables the Preheat
function. Eco mode is enabled by default, during the initial appliance
start up.
4.6

Setting the heating control device

Observe the operating instructions of the heating controller. This shows
you:
▶ how to set the room temperature.
▶ how to heat economically and save energy.
Heating/DHW via time program (Key control accessories)
Time programs are available with Key control accessories fitted. If a time
program is available and the heating/DHW mode is set on Auto press the
ok key to select Advance.
Auto: Heating/DHW mode is switched on and off according to
programmed times.
Advance: Switch to Advance to move to the next central heating/DHW
on or off time.
4.7

Operating the menu

Opening and closing the menu
▶ To open the menu, press the
▶ To exit the menu, press the
-or-
▶ Press the d key.
Changing the setting values
▶ To highlight a menu item, press the  key or the  key.
▶ Select the menu item with the ok key.
▶ To change the value, press the  or  key.
▶ Press the ok key.
The new value is saved.
Exiting the menu without saving values
▶ Press the d key.
10
key.
key again.
4.8

Settings in the menu

The factory settings are highlighted in the following table.
Menu item
Function definition
1)
Heating mode
• On
• Auto: Activate time program.
• Once: Heating is on from the first programmed on time
to the last programmed off time without off periods.
• Off
1)
Heat. time prog.
Timer for heating: Weekday(s) selection, day program and
timer adjustment ( 5.1 "Setting the time program",
page 11).
DHW preheat
• On
1)
• Auto
1)
• Once
• Off
1)
DHW time prog.
Timer for hot water: Weekday(s) selection, day program
and timer adjustment ( 5.1 "Setting the time program",
1)
page 11).
Boiler status
Current system values including the pressure indicator.
Information
The current system values and the active operating
conditions can be called up in the Information menu.
Changes are not possible.
• System pressure
• Hot water Temp. (DHW temperature)
• Weather comp. (where fitted)
• System Fill (automatic filling)
• Key (Type of installed key is shown, e.g. "Comfort + RF
Key")
• Internet connect.
Energy consump.
Display Gas consumption
• Last 24h
• Last 30 days
Settings
• Time: Set the current time.
• Date: Set the current date.
• DST: enable automatic time shift change summer/
winter time
• Parental lock
– On
– Off
• Display
– Switch off after: Set the time after which the
display is switched off.
– Brightness: Set the display brightness.
• Key illum. (Key illumination)
• Language: Change the language of the menu and the
menu items.
1)
• Units
Cleaning funct.
Boiler keypad is disabled for 15 seconds.
3)
Emergency mode
• On: Set the desired heating flow temperature by
pressing back or menu key after selecting On.
• Off
2)
Start filling
• On
– Are you sure there is no leak in your heating
system?
– Cancel now?
– Start filling
• Off
1) Only available with installed Key (accessories)
2) Only available with automatic filling facility (accessory)
3) Allows manual control of heating during loss of Radio Frequency (RF) Key signal
Table 7 Settings Menu
Condens 4700iW – 6721864484 (2023/04)
2)
1)
1)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gc4700iw 24/25 cGc4700iw 24/30 c

Table of Contents