4.INVERTER CONNECTION
CAUTION
As different inverters have different connection rules, please find the battery connection
rules in the inverter user manual and follow it.Here list the basiclly connection step between
our battery and unknown brand inverter for your reference.
WARNING
Cut off main power before operation the inverter and battery, after connection and setting
is done, Turn on the main power.

4.1 Connection step

Please follow reference steps to implement the connection between battery and inverter:
1.Check the inverter user manual or confirm with the inverter reseller whether the inverter
have communication BMS internal:
1)
If inverter is without communication BMS RS485/CAN, treat our lithium ion battery as
AGM battery
①Connect the postive and negative cables between battery and inverter +/+,-/-(Check the
ring terminal size in inveter user manual ,make sure its workable and connect battery and
inverter)
②Select "AGM"mode(Sealed lead acid battery) in the inverter
③Setting the battery data on inverter like charging voltage,charging cut off voltage,dis-
charging cut off voltage ,charging current ,charging cut off current, discharging current
etc(You can consult battery seller to get those data) WARNING: Set those data before
use,otherwise it will damage the battery!
2) If inverter has communication BMS internal,See step NO.2
2.Check the "Battery connection"part from inverter user manul, Find the postive and
negative cables' ring terminal size and connect the cables. Make sure polarity at both the
15