3)
Press the <ENTER> button.
f The screen for the selected item is displayed.
4)
Press as to select [FREE GRID].
5)
Press qw to select [ON].
6)
Press the <ENTER> button.
f The [FREE GRID] screen is displayed.
7)
Press as to select [INITIALIZE].
8)
Press the <ENTER> button.
f The confirmation screen is displayed.
9)
Press qw to select [OK], and press the <ENTER> button.
Note
f Each correction data for [KEYSTONE], [CORNER/PINCUSHION], [CURVED CORRECTION], [PC-1], [PC-2], and [PC-3] cannot be
initialized at once.
To initialize all the correction data, select each item and execute [INITIALIZE] individually.
f When the projector is initialized by one of the following methods, all data in [FREE GRID] are initialized.
g When initialized by selecting the [PROJECTOR SETUP] menu → [INITIALIZE] → [FACTORY RESET]
g When initialized by setting the [PROJECTOR SETUP] menu → [INITIALIZE] → [USER SETTINGS] → [OTHER USER SETTING] to
[INITIALIZE]

[CONVERGENCE]

Correct the position shift of the three primary colors of red, green, and blue in the projected image.
1)
Press as to select [CONVERGENCE].
2)
Press qw to switch the item.
f The items will switch each time you press the button.
[OFF]
[ON]
f Proceed to Step 3) when [ON] is selected.
3)
Press the <ENTER> button.
f The [CONVERGENCE] screen is displayed.
4)
Press as to select the color to adjust, and press the <ENTER> button.
5)
Press as to select the position on the projected image to adjust and adjustment direction, and
press qw to adjust.
Note
f The picture quality may degrade when the convergence function is used.
f Perform the adjustment by the convergence function when the projected image has stabilized.
When using the Zoom Lens (Model No.: ET-D3LEW200) or the Fixed-focus Lens (Model No.: ET-D3LEU100), it is recommended to adjust
the image after at least an hour has elapsed with the focus test pattern displayed.
When using a projection lens other than the Zoom Lens (Model No.: ET-D3LEW200) and the Fixed-focus Lens (Model No.: ET-D3LEU100),
it is recommended to adjust the image after at least 30 minutes have elapsed with the focus test pattern displayed. For details of the test
pattern, refer to "[TEST PATTERN] menu" (x page 210).
Chapter 4 Settings — [POSITION] menu
Disables the convergence function.
Enables the convergence function.
ENGLISH - 125