SPECIFICATIONS

Unit dimensions:
MODEL(Btu/h)
BODY DIMENSION(WxHxD)(mm)
445x320x415
5000~6000
450x346x535
450x346x535
7000~9000
450x346x585
675x350x450.6
675x350x450.6
450x350x675
9000~12000
560x400x640
600x380x560
780x428x660
15000~24000
660x428x780
Choose the right cable size
The size of the power supply cable, signal cable, fuse, and switch needed is determined by the maximum current of the unit. The
maximum current is indicated on the nameplate located on the side panel of the unit. Refer to this nameplate to choose the right
cable, fuse, or switch.
Minimum norminal cross-sectional area of conductors:
Rated Current of Appliance (A)
> 3 and
6
> 6 and
10
> 10 and
16
> 16 and
25
> 25 and
32
> 32 and
40
Note: For the different customization requirements, the deepth of the panel
may be slightly different. So the dimension of "D" is for reference only.
Nominal Cross-Sectional Area (mm²)
0.75
1
1.5
2.5
4
6
19