IBM 366 Problem Determination And Service Manual page 46

Hide thumbs Also See for 366:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 8863," on page 105 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)", that step must be performed only by a
trained service technician.
Error code
Description
00180600
PCI built-in self-test failure.
00180700,
General PCI error.
00180800
00181000
PCI error.
30
IBM xSeries 366 Type 8863: Problem Determination and Service Guide
Action
1. If the error code indicates a particular PCI or
PCI-X slot or device, remove that device.
Note: Slot 0 indicates the I/O board.
2. Reseat the following components:
a. Each adapter
b. (Trained service technician only, if the
specified board is a FRU) The board indicated
in the error code. (See Chapter 3, "Parts
listing, Type 8863," on page 105, to determine
CRU or FRU status.)
3. Replace the components listed in step 2 one at a
time, in the order shown above, restarting the
server each time.
1. Make sure that no devices have been disabled in
the Configuration/Setup Utility program.
2. Reseat the following components:
a. Failing adapter
Note: If an error LED is lit on the PCI-X
board or on an adapter, reseat that adapter
first; if no LEDs are lit, reseat each adapter
one at a time, restarting the server each time,
to isolate the failing adapter.
b. (Trained service technician only) PCI-X board
3. Replace the components listed in step 2 one at a
time, in the order shown, restarting the server
each time.
1. Remove the adapters from the PCI or PCI-X
slots.
2. Reseat the following components:
a. Failing adapter
Note: If an error LED is lit on the PCI-X
board or on an adapter, reseat that adapter
first; if no LEDs are lit, reseat each adapter
one at a time, restarting the server each time,
to isolate the failing adapter.
b. (Trained service technician only) PCI-X board
3. Replace the components listed in step 2 one at a
time, in the order shown, restarting the server
each time.