Vacuum Assembly; Remove The Inlet Restrictor; Attaching The Vacuum Tubes; Attach The Collection Bag - Craftsman 358.799432 Operator's Manual

12 amp motor 195 mph/405 cfm electric blower vacuum
Table of Contents

Advertisement

3lower outlet
Blower Tube/Nozzle
VACUUM
ASSEMBLY
NOTE: Assembly
instructions
for using
your unit as a blower are explained
in
the previous
section.
If you have already assembled
your
unit for use as a blower, remove the
blower tube/nozzle.
REMOVE
THE INLET RESTRICTOR
An inlet restrictor
is used when using
your unit as a blower. This restrictor
is
not used during vacuum
use and must
be removed
during assembly
for vacu-
um use.
NOTE: Be sure to keep the inlet re-
stricter for using your unit as a blower.
1. Ensure unit is stopped and extension
cord is unplugged.
2. Open the inlet cover by inserting the
tip of a screwdriver
into the latch
area on the vacuum
inlet cover.
Gently tilt handle of screwdriver
to-
ward the front of the unit while pull-
ing up on the vacuum
inlet cover
with your other hand.
Latch Area
Impeller
Vacuum inlet Cover
3. Turn the inlet restrictor counterclock-
wise and remove it from the unit. Do
not close the inlet door. You will next
attach the vacuum tubes.
,e,et ' -iYiJI'I
ATTACHING
THE VACUUM
TUBES
There are 2 vacuum
tubes, an upper
and lower tube. The upper tube is cut
straight on both ends and attaches to
the blower unit. The lower tube at-
taches
to the upper tube, and has an
angled end that you point toward the
ground during vacuum
use.
1. Ensure unit is stopped and exten-
sion cord is unplugged.
2. Locate the arrows on the upper vac-
uum tube and on the vacuum
inlet
area of the unit.
Upper Vacuum Tube
3. While holding the inlet cover open,
align the arrows and insert the vac-
uum tube into the opening. Twist the
tube clockwise
until it is seated. A
second arrow on the vacuum
tube
will align with the arrow on the unit
once the tube is twisted completely
into place.
Align arrows on tube & unit
4. To attach the lower vacuum tube to
the upper vacuum
tube, first align
the arrows on the two tubes. Then,
press the two tubes together until
the lower tube is securely
seated in
the upper tube (about 3 inches).
Upper Tube
Lower Tube
ATTACH THE COLLECTION
BAG
Slide the opening
of the collection
bag
over the blower outlet. Pull the velcro
strap tightly through the buckle and se-
cure to the velcro tabs.
NOTE: Make sure the velcro strap is
located on the blower outlet as shown
below. Also, make sure the zipper on
the bag is completely
closed.
Velcro Strap _.
//
I
bollection
_
,r-...._
Bag
Blower Outlet