The integrated control is equipped with an LED light for troubleshooting. The diagnostic codes are listed below in table 4.
RED LED
Flash Code
Off
On
1
Heartbeat
1
2
3
4
5
6
7
8
9
10
11
12
13
Note 1
Note
Note
1
É É
ON
É É
É É
OFF
É É É É É É É É É É É É É É É É É É É É É É É É
É É É É É É É É É É É É É É É É É É É É É É É É É É É
DEMAND
CAI
É É É É É É É É É É É É É É É É É É É É É É É É É É É
IGNITOR
GAS VALVE
INDOOR BLOWER
*Blower on time will be 30 seconds after flame is sensed. Blower off time will depend on "OFF TIME" Setting.
No power to control or board fault detected
Board fault detected,
Control powered - displayed during all modes of operation if no errors are detected
Reverse Line Voltage Polarity
Improper Earth Ground
Burner failed to light, or lost flame during heat demand
Low Flame Signal - check flame sensor
Watchguard - burner failed to light, exceeded maximum number of retries or recycles.
Not Used
Primary or Secondary Limit Open or Watchguard Mode - Limit Switch Open longer than 3 min­
utes
Rollout Switch Open
Pressure Switch failed to close or opened during heat demand
Watchguard - Pressure Switch opened 5 times during one heat demand
Pressure Switch stuck closed prior to activation of combustion air inducer
Flame Sensed without gas valve energized
Low Line Voltage
A "Heartbeat" is indicated by a "Slow Flash" - 1 sec on 1 sec off, repeating
Error codes are indicated by a "Rapid Flash" - the LED flashes X times at 1/2 sec on 1/2 sec
off, remains off for 3 sec, then repeats
Last 10 error codes are stored in memory including when power is shut off to the unit. - To recall,
press and release button, most recent will be displayed first, LED off for 3 sec, then next error
code is displayed, etc. To clear error codes, depress and hold button longer than 5 seconds.
ELECTRONIC IGNITION
15
Pre -Purge
Ignitor Warm-up
É É É É É É É É É É
É É É É É É É É É É
TABLE 4
Diagnostic Codes / Status of Furnace
Notes
34
38
Trial for
Blower "On"*
Ignition
Delay
É É É É É É É É É É É É É
FIGURE 4
Page 9
80
5 SEC
Post
Purge
É É É É É É É É É