Axis Q1604 E User Manual page 8

Table of Contents

Advertisement

AXIS Q1604–E Network Camera
Hardware overview
I/O connector
Note
For technical specifications, see
I/O terminal connector - Use in applications for e.g. motion detection, event triggering, time lapse recording and alarm notifications.
In addition to an auxiliary power and a GND pin, the I/O terminal connector provides the interface to:
Digital output — For connecting external devices such as relays and LEDs. Connected devices can be activated by
the VAPIX® Application Programming Interface, output buttons on the Live View page or by an Action Rule. The
output will show as active (shown under System Options > Ports & Devices) if the alarm device is activated.
Digital input — An alarm input for connecting devices that can toggle between an open and closed circuit, for
example: PIRs, door/window contacts, glass break detectors, etc. When a signal is received the state changes and
the input becomes active (shown under System Options > Ports & Devices).
Note
The I/O connector is connected to the housing (fan/heater) on delivery, and will trigger an input port event to indicate a fan
or heater error when activated. See
Function
Pin
1
GND
2
3.3 V DC Power
3
Digital Input
4
Digital Output
All manuals and user guides at all-guides.com
DC power input
page 52
.
Events, on page 31
Notes
Ground
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
Connect to GND to activate, or leave floating (unconnected)
to deactivate.
Internal connection to ground when activated, floating
(unconnected) when deactivated. If used with an inductive
load, e.g. a relay, a diode must be connected in parallel with
the load, for protection against voltage transients.
for information on how to set up an event.
8
Specifications
Max load = 50 mA
0 to +40 V DC
Max load =100 mA
Max voltage = +40 V DC

Advertisement