To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
6" (15.2 cm) Round Vent System
Vent Piece
45° elbow
90° elbow
6" (15.2 cm) wall cap
3¹⁄
" x 10" (8.3 cm x 25.4 cm)
4
to 6" (15.2 cm)
3¹⁄
" x 10" (8.3 cm x 25.4 cm)
4
to 6" (15.2 cm) 90° elbow
Example vent system
90˚ elbow
2 ft (0.6 m)
Maximum Recommended Length
1 - 90° elbow
1 - wall cap
8 ft (2.4 m) straight
Length of 7" (17.8 cm) system
3¹⁄
" x 10" (8.3 cm x 25.4 cm) Vent System
4
Vent Piece
3¹⁄
" x 10" (8.3 cm x 25.4 cm)
4
90° elbow
3¹⁄
" x 10" (8.3 cm x 25.4 cm)
4
flat elbow
3¹⁄
" x 10" (8.3 cm x 25.4 cm)
4
wall cap
6
Round
2.5 ft
(0.8 m)
5.0 ft
(1.5 m)
0.0 ft
(0.0 m)
4.5 ft
(1.4 m)
5.0 ft
(1.5 m)
Wall cap
6 ft (1.8 m)
= 50 ft (15.2 m)
= 5.0 ft (1.5 m)
= 0.0 ft (0.0 m)
= 8.0 ft (2.4 m)
= 13.0 ft (3.9 m)
5.0 ft
(1.5 m)
12.0 ft
(3.7 m)
0.0 ft
(0.0 m)
Example vent system
3
" x 10"
¹⁄₄
(8.3 x 25.4 cm)
elbow
6 ft (1.8 m)
2 ft
(0.6 m)
Maximum Recommended Length
1 - 90° elbow
8 ft (2.4 m) straight
1 - wall cap
Length of system
Non-Vented (recirculating) Installations Through the
Soffit/Cabinet
If it is not possible to vent cooking fumes and vapors to
the outside, the range hood can be used in the non-vented
(recirculating) version, using a recirculation kit. The recirculation
kit Part Number is W10490330. See "Assistance or Service"
section to order.
For non-vented (recirculating) installations only, the range hood
can be vented indoors through the top of the cabinet or soffit.
Through Cabinet
A
G
B
D
F
E
A. Ceiling
B. Vent cover
C. Soffit
D. 6" (15.2 cm) vent
E. Range hood
NOTE: 12" (30.5 cm) high cabinets without a soffit may allow
the 6" (15.2 cm) vent and vent cover to be seen.
Wall cap
= 35 ft (10.7 m)
= 5.0 ft (1.5 m)
= 8.0 ft (2.4 m)
= 0.0 ft (0.0 m)
= 13.0 ft (3.9 m)
Through Soffit
G
F
H
F. Cabinet
G. Wall
H. 17" (43.2 cm) min.
vent cover height
A
B
C
D
E