Description

The smoke alarm is a device used to detect smoke. The smoke alarm does not detect heat or gas. The device is suitable for indoor use only. If the device detects smoke, the alarm will sound and the indicator will flash red continuously until the smoke is eliminated.
Device Overview

  1. Test button / Smoke indicator
  2. Siren
  3. Mounting plate
  4. Screw

Safety

  • Read the manual carefully before use. Keep the manual for future reference.
  • Only use the device for its intended purposes. Do not use the device for other purposes than described in the manual.
  • Do not use the device if any part is damaged or defective. If the device is damaged or defective, replace the device immediately.
  • The device has a limited lifetime. Replace the device 8 years after the date of purchase. Write the purchase date on the manual for future reference.

Installation

  • Do not use the device outdoors.
  • Do not expose the device to water or moisture.
  • Install the device out of the reach of children.
  • Install at least one device at each floor level. Preferably install one device in each recommended area.
  • Do not install the device in bathrooms, toilets or other rooms where the device can be triggered by steam or condensation.
  • Do not install the device in rooms with temperatures below 0°C or above 40°C.
  • Do not install the device in dusty or dirty environments.
  • Do not install the device near doors and windows.
  • Do not install the device near radiators or air vents in walls or ceilings.
  • Do not install the device behind curtains or furniture.
  • Do not use rechargeable batteries in order to prevent malfunctions.
  • Do not paint the device.
    Installation

Recommended installation locations *)

Area Yes No
Living room X
Dining room X
Kitchen X
Bathroom / Toilet X
Bedroom X
Hallway X
Attic X
Basement X
Garage X
Boiler room X

*) The installation requirements may differ per region. Contact your local authorities for possible additional requirements.

Use

Smoke indicator

Normal operation The indicator will flash red once every 30 seconds. ---
Smoke detection The alarm will sound and the indicator will flash red continuously until the smoke is eliminated. Eliminate the smoke.
Low-battery warning The alarm will beep shortly every minute and the indicator will flash. Replace the battery.

Testing the alarm
The alarm must be tested weekly to ensure correct operation.

  1. Press and hold the test button for a few seconds. the alarm will sound and the indicator will flash.
  2. Release the test button.

Cleaning and maintenance

  • Do not use cleaning solvents or abrasives.
  • Do not clean the inside of the device.
  • Do not attempt to repair the device. If the device does not operate correctly, replace it with a new device.
  1. Replace the battery at least once a year or immediately when the device gives a low-battery warning.
  2. Clean the outside of the device at least once a month. Use a vacuum cleaner with brush nozzle to clean the outside of the device.

Technical data

Battery type 9V battery (PP3)
Alkaline battery:
6LR61 (IEC) / 1604A (ANSI/NEDA)
Zinc-carbon battery:
6F22 (IEC) / 1604D (ANSI/NEDA)
Battery life 1 year
Standby current < 8 μA
Alarm current < 16 mA
Alarm volume > 85 dB(A) (3 m)
Ambient temperature 0~40°C
Relative humidity 25~85%

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Nedis DTCTS20WT - Smoke Alarm Manual

Advertisement

Need Assistance?

Do you have a question about the DTCTS20WT that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents