Mitsubishi Electric FR-E800 Instruction Manual page 240

Advertisement

 Parameter write enabled during operation (Pr.77 = "2")
• Parameters can always be written.
• The following parameters cannot be written during operation if Pr.77 = "2". To change the parameter setting value, stop
the operation.
Pr.
Stall prevention operation level compensation
23
factor at double speed
40
RUN key rotation direction selection
48
Second stall prevention operation level
60
Energy saving control selection
61
Reference current
Stall prevention operation reduction starting
66
frequency
71
Applied motor
79
Operation mode selection
80
Motor capacity
81
Number of motor poles
82
Motor excitation current
83
Rated motor voltage
84
Rated motor frequency
90 to 94
(Motor constant)
95
Online auto tuning selection
96
Auto tuning setting/status
178 to 197
(Input/output terminal function selection)
261
Power failure stop selection
277
Stall prevention operation current switchover
289
Inverter output terminal filter
291
Pulse train input selection
292
Automatic acceleration/deceleration
293
Acceleration/deceleration separate selection
298
Frequency search gain
313 to 322
(Extension output terminal function selection)
329
Digital input unit selection
415
Inverter operation lock mode setting
418
Extension output terminal filter
420, 421
(Electronic gear)
450
Second applied motor
451
Second motor control method selection
453
Second motor capacity
454
Number of second motor poles
455
Second motor excitation current
Name
Pr.
456
Rated second motor voltage
457
Rated second motor frequency
458 to 462
(Second motor constant)
463
Second motor auto tuning setting/status
507
Display/reset ABC relay contact life
508
Display/reset ABC2 relay contact life
525 to 531
(Extension input terminal function selection)
538
Current position retention selection
541
Frequency command sign selection
560
Second frequency search gain
561
PTC thermistor protection level
570
Multiple rating setting
574
Second motor online auto tuning
Inverter output fault detection enable/disable
631
selection
639, 640
(Brake sequence)
660 to 662
(Increased magnetic excitation deceleration)
SF-PR slip amount adjustment operation
673
selection
699
Input terminal filter
702
Maximum motor frequency
706, 707, 711,
712, 717, 721,
(PM motor tuning)
724, 725, 1412
(Motor starting resistance tuning
720, 737
compensation coefficient 2)
738 to 746, 1413
(Second PM motor tuning)
800
Control method selection
858
Terminal 4 function assignment
859
Torque current/Rated PM motor current
Second motor torque current/Rated PM motor
860
current
868
Terminal 1 function assignment
979 to 981
(Position accuracy compensation gain 1 to 3)
998
PM parameter initialization
999
Automatic parameter setting
1002
Lq tuning target current adjustment coefficient
1292
Position control terminal input selection
1293
Roll feeding mode selection
8. (E) Environment Setting Parameters
Name
8.10 Parameter write selection
1
2
3
4
5
6
7
8
9
10
239