E-Rds; Configuration - Canon imageRUNNER 2520 Series Service Manual

Hide thumbs Also See for imageRUNNER 2520 Series:
Table of Contents

Advertisement

When a license option is displayed in Procedure (4), 001 1 is displayed. The last "1" shows
that the license is validated by license authentication.
After the license is erased, the last number is changed to "2".
When the option is standard, the last number shows "3" which means disable for license
transfer.
Details about the last number:
1: The function is validated.
2: The function is invalidated, or a license is transferred.
3: The function is invalidated, or the license does not exist.
4
4-38
All manuals and user guides at all-guides.com

#E-RDS

Configuration

Settings related to e-RDS are described below.
Item
E-RDS
SWITCH
RGW-
ADDRESS
RGW-PORT 443
CNT-DATE
CNT-INTV
COM-TEST
COM-LOG
SCALLCMP
Default
Setting range
Description
0
0 or 1
e-RDS OFF/ON setting (0:OFF / 1:ON)When
used (ON), the counter information and error
information are sent to UGW.Default: 0 (OFF)
URL of UGW Character string
URL of UGWDefault: URL of actual
length:129byte
UGWCharacter string length: 129 bytes (including
(including NULL,
NULL, one-byte codes only)
one-byte codes only)
1-65535
Port No. of UGW Default: 443Setting range: 1 to
65535
Setting of the date of sending the counter
information to the server (Valid after input of
license).
Set the start date of the schedule to send the
counter information to the server using a third
party expansion function of E-RDS.
Refer to the user mode date setting.
(12 digits: YYYYMMDDHHMM)
YYYY: Year MM: Month DD: Day
HH: Hour MM: Minute
24
1-168 (on a weekly
Setting of the interval of sending the counter
basis)
information to the server (Valid after input of
license).
Set the interval of sending the counter information
to the server using a third party expansion
function of E-RDS.
Execution of communication test An attempt
is made to connect to UGW, judges whether
connection is successful, and displays "COM-
TEST OK" or "COMTEST NG" as the judgment
result.
Details of communication test result. The log of
errors in communication with UGW is displayed.
The error information includes the error occurrence
time, error code, and details of the error.Maximum
log count: 5Error information length: Max. 128
characters (excluding NULL)
Repair completion process (call button function)
Used when the service personnel has completed
the requested repair.
T-4-49
T-4-49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Imagerunner 2530 seriesImagerunner 2525 series

Table of Contents