Figures & Tables - Nordyne VG7TC-FS Installation Instructions Manual

Two-stage condensing gas furnaces with fixed & variable speed blowers
Table of Contents

Advertisement

*TC 95.1% Upflow / Horizontal Furnace
Cabinet
Dim.
Size
"A"
'B' Cabinet
17 1/2
'C' Cabinet
21
'D' Cabinet
24 1/2
NOTE: Dimensions shown in inches.
*TL 95.1% Downflow Furnace
Cabinet
Dim.
Size
"A"
'B' Cabinet
17 1/2
'C' Cabinet
21
'D' Cabinet
24 1/2
NOTE: Dimensions shown in inches.
32
FIGURES & TABLES
Dim.
Dim.
"B"
"C"
15 7/8
16 1/8
19 3/8
19 5/8
22 7/8
23 1/8
T-stat
2 3/4
(Ø 7/8)
22 1/2
Electric
(Ø 7/8)
25 3/8
22 1/2
(Ø 1 5/8)
Vent pipe
(Ø 3")
28
Condensate
(Ø 1 1/16)
LEFT SIDE
Dim.
Dim.
"B"
"C"
15 7/8
16 1/8
19 3/8
19 5/8
22 7/8
23 1/8
28
25 1/4
Electric
(Ø 7/8)
22 1/4
Gas (Ø 1 5/8)
25 1/2
22 1/2
Vent pipe
(Ø 3")
Cond. (Ø 1 1/16)
LEFT SIDE
Figure 28. *TC & *TL Cabinet Dimensions
TOP VIEW
B
19
3 1/4
Combustion Air
A
Vent pipe
Gas
FRONT VIEW
TOP VIEW
B
19
Combustion
Flue
3
A
FRONT VIEW
BOTTOM VIEW
C
Front Brace
Bottom
Panel
T-stat
Electric (Ø 7/8)
(Ø 7/8)
(Ø 3")
22 1/2
Gas (Ø 1 5/8)
4 Knockouts
(both sides)
1
Cond. (Ø 1 1/16)
23
RIGHT SIDE
BOTTOM VIEW
C
Front
Brace
Air
7 1/2
T-stat
(Ø 7/8)
22 1/4
Electric
(Ø 7/8)
Gas
(Ø 1 5/8)
25
Vent pipe
(Ø 3")
22 1/2
25 3/8
Cond. (Ø 1 1/16)
RIGHT SIDE
15
1 1/4