6. DRY OPERATION
Refer to the Table 2.
During the dry mode operation, the fan speed setting can not be changed.
( Fig.3 : Compressor Control based on Room Temperature )
Room
temperature
X zone
Ts+0.5°C
J zone
Ts -1.5°C
Y zone
( Fig.4 : Indoor Fan Control )
Compressor
ON
OFF
Indoor fan
Setting air flow
Indoor fan
(as shown in Table 4)
S-Lo
OFF
10
Room
temperature
Ts+1.5°C
Ts -0.5°C
30
60
01-04
180
60
180
60
10
30
(SEC)