Blower Data
EL196UH090XE48C PERFORMANCE (Less Filter)
External
Static
High
Pressure
(Black)
in. w.g.
cfm
0.00
1723
0.10
1684
0.20
1645
0.30
1626
0.40
1593
0.50
1564
0.60
1529
0.70
1481
0.80
1395
0.90
1290
1.00
1123
EL196UH110XE60C PERFORMANCE (Less Filter)
Bottom Return Air, Side Return Air with Return Air from
External
Both Sides or Return Air from Bottom and One Side.
Static
Pressure
Medium-
in. w.g.
High
High
(Black)
(Brown)
cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts
0.00
2197 640 1964 429 1791 330 1658 277 1488 210 2122 634 1892 424 1722 333 1635 266 1452 194
2160 658 1911 446 1742 346 1620 291 1438 220 2093 644 1858 438 1688 341 1590 281 1410 205
0.10
0.20
2124 676 1858 464 1693 361 1582 306 1388 230 2064 655 1824 451 1653 349 1546 296 1367 216
0.30
2084 688 1822 477 1658 373 1536 314 1336 239 2033 669 1788 467 1619 363 1511 306 1321 228
0.40
2051 703 1797 492 1615 386 1497 328 1288 250 1996 686 1749 482 1580 376 1473 322 1275 239
0.50
2024 718 1754 508 1581 397 1452 342 1247 261 1971 704 1709 498 1543 392 1436 330 1230 251
0.60
1993 734 1716 519 1537 413 1414 353 1203 270 1941 720 1676 512 1503 403 1387 347 1184 262
0.70
1942 742 1680 535 1500 423 1381 361 1157 277 1903 734 1644 524 1468 419 1351 356 1140 271
1877 721 1644 547 1465 434 1342 372 1121 288 1855 732 1606 542 1424 430 1313 369 1105 282
0.80
0.90
1789 693 1614 563 1423 450 1294 386 1061 300 1780 707 1571 554 1386 443 1273 380 1061 293
1.00
1696 654 1580 573 1395 461 1267 396 1014 310 1675 670 1535 569 1352 456 1238 392 1019 302
Model Number
All Models
Model Number
All Models
Factory Setting
Air Volume / Watts at Various Blower Speeds
Medium-High
(Brown)
Watts
cfm
Watts
379
1511
248
395
1480
264
410
1448
281
422
1414
295
435
1381
307
451
1347
322
465
1308
335
463
1288
346
442
1247
359
412
1211
369
361
1097
351
Air Volume / Watts at Different Blower Speeds
Medium-
Medium
Low
(Blue)
(Yellow)
Allowable Heating Speeds
Red
Yellow
Allowed
Factory Setting
Allowable Circulation Speeds
Red
Yellow
Not Allowed
Medium
(Blue)
cfm
Watts
1389
191
1356
209
1323
226
1294
238
1245
253
1210
261
1175
274
1143
288
1103
297
1067
309
1011
319
Single Side Return Air - Air volumes in bold (over 1800
cfm) require Optional Return Air Base and field fabricated
transition to accommodate 20 x 25 x 1 in. air filter in order to
maintain proper air velocity.
Medium-
Low
High
(Red)
(Black)
TABLE 16
Blue
Allowed
TABLE 17
Blue
Not Allowed
Page 55
Medium-Low
(Yellow)
cfm
Watts
cfm
1302
169
1194
1269
180
1147
1236
191
1101
1195
204
1070
1158
213
1022
1120
225
1084
237
1039
250
1003
262
960
272
917
281
Medium-
Medium
High
Low
(Blue)
(Brown)
(Yellow)
Brown
Allowed
Brown
Not Allowed
Low
(Red)
Watts
136
142
149
162
172
983
182
943
193
897
204
860
214
813
225
772
230
Low
(Red)
Black
Not Allowed
Black
Not Allowed