Advertisement

CN05 Gas Sensor
3-4 5vdc
CN01
1) KEY OUT-1
2) KEY OUT-2
3) KEY OUT-3
4) KEY OUT-4
5) KEY OUT-5
6) KEY OUT-6
7) KEY OUT-7
8) KEY OUT-8
9) KEY OUT-9
10) KEY IN-1
11) KEY IN-2
12) KEY IN-3
13) KEY IN-4
14) KEY IN-5
15) KEY IN-6
16) KEY IN-7
Door Interlock Ass'y
Main PCB
RY209
Fan
CN202 Pwr & Relay
1-(CN201-1) Main
3-(CN201-1) TT
5-(CN201-1) Vent Low
7-(CN201-1) Vent High
9-(CN201-1) Vent Boost
CN401 Door Connector
1 Door sw
3 Door sw
3-5 12vdc
4-5 5vdc
RY206
RY208
RY207
Bright
TT
Louver
Relay
RY201
Main
Relay
CN201 Relay, Lamp, SMPS
1 Line 1
3-1 RY202 In Rush Relay Neutral Contact
5-1 RY206 Bright Lamp Relay Neutral Contact
5-1 RY205 Night Lamp Relay Neutral Contact
7-1 RY207 Louver
The fuse is located on the noise filter.
1. Disconnect power and remove grille and Assembly
Control Box.
2. Replace the fuse.
3. When 20A fuse blows out by the operation of interlock
monitor switch failure, replace the primary interlock
switch, secondary interlock switch, door sensing switch,
interlock monitor switch and power relay.
4. When the above four switches operate properly, check
if any other part such as the control circuit board, blower
motor or high voltage transformer is defective.
RY204
Power Low
RY05
Relay
Night
Relay
RY203
Power
High Relay
RY202 In
Rush Relay

Advertisement