Error Messages - Dell VxRail VP-760 Manual

Table of Contents

Advertisement

Error messages

The error messages that are displayed on the screen during POST or captured in the system event log (SEL), or LifeCycle (LC)
log.
The following table describes the details of the error message HWC8010:
Error code
HWC8010
Message
The System Configuration Check operation that is resulted in the following
issue involving the indicated component type
Arguments
Riser, floating card (fPERC, adapter PERC, BOSS), backplane, processor, cable, or other components
Detailed Description
The issue that is identified in the message is observed in the System Configuration Check operation.
Recommended
Do the following and retry the operation:
Response Action
1. Disconnect the input power.
2. Check for proper cable connection and component placement. If the issue persists, contact the
Category
System Health (HWC = Hardware Config)
Severity
Critical
Trap/EventID
2329
The following table describes the details of the error message HWC8011:
Error code
HWC8011
Message
The System Configuration Check operation that is resulted in multiple
issues involving the indicated component type
Arguments
Riser, floating card (fPERC, adapter PERC, BOSS), backplane, processor, cable, or other components
Detailed Description
Multiple issues are observed in the System Configuration Check operation.
Recommended
Do the following and retry the operation:
Response Action
1. Disconnect the input power.
2. Check for proper cable connection and component placement. If the issue persists, contact the
Category
System Health (HWC = Hardware Config)
Severity
Critical
50
Configuration information
service provider.
service provider.

Hide quick links:

Advertisement

Table of Contents
loading