Safe Mode Switch - National Instruments NI Vision CVS-1454 User Manual

Hide thumbs Also See for NI Vision CVS-1454:
Table of Contents

Advertisement

Chapter 2
LEDs, DIP Switches, and Connectors

SAFE MODE Switch

NI CVS-1450 Series User Manual
Figure 2-3 shows the location of the DIP switches on the NI CVS-1450
device.
ON
To start the NI CVS-1450 device in safe mode, move the SAFE MODE
switch to the ON position and reset the NI CVS-1450 device. Use safe
mode to reconfigure TCP/IP settings and to download or update software
from the development computer.
Downloading incorrect software to the NI CVS-1450 device may cause it
to hang during restart or become inaccessible over the network. Powering
on or resetting the NI CVS-1450 device in safe mode starts the
NI CVS-1450 device but does not start the embedded LabVIEW Real-Time
engine. To resume normal operations, restart the NI CVS-1450 device with
the SAFE MODE switch in the OFF position.
Figure 2-3. DIP Switches
2-4
NI 1454
Compact Vision System
ni.com