Connect the positive wire from the power source to the positive/live (+/L) termi-
nal on the terminal block.
Figure 2.5
5.
Connect the negative wire from the power source to the negative/neutral (-/N)
terminal on the terminal block.
6.
Install the supplied metal jumper between terminals 2, 4 and 6 to connect the
surge ground terminals to the chassis ground terminal. The surge ground termi-
nals are used as the ground conductor for all surge and transient suppression cir-
cuitry internal to the unit.
RUGGEDCOM RSG2200
Installation Manual, 01/2020, C79000-G8976-1043-15