Download Print this page

Cornelius pmnice systems Specifications page 4

Ice systems, series "xtreme", compatible icemaker "x" series, remote condensers, cornelius bagger

Advertisement

C
U
B
E
34"
R
S
ACS50
39"
IACS224
39"
IACS227
4
Series 50†
DIMENSIONS/CAPACITY
Model
Nominal
Number
Capacity
ACS50
46 lbs.
15"w x 24"d x 34"h
ARI CERTIFIED PERFORMANCE
Ice Harvest
Potable Water
Model
Rate
Use
Number
lbs. per 24 hrs.
per 100 lbs.
ACS50
38
38.5
Rated in accordance with ARI Standard 810-91 and 820-88.
PRODUCTION CHART
AIR-COOLED
Water Temperature (˚F)
Air Temp (˚F)
50
70
46 lbs.
80
44 lbs.
90
42 lbs.
SPECIFICATIONS
Model
Refrigerant Standard
Number Condenser
Type
Electrical
ACS50SL Air-Cooled
R-134a
115/60/1
†Limited lifetime warranty not applicable to this model.
Series 200
DIMENSIONS/CAPACITY
Model
Nominal
Number
Capacity
IACS224/IWCS224
251 lbs
24"w x 24"d x 39"h
IACS227/IWCS227
326 lbs
27"w x 28"d x 39"h
ARI CERTIFIED PERFORMANCE
Ice Harvest
Potable Water
Model
Rate
Use
Number
lbs. per 24 hrs.
per 100 lbs.
IACS224
150
25.0
IWCS224
145
22.0
IACS227
240
27.0
IWCS227
240
27.0
Rated in accordance with ARI Standard 810-91 and 820-88.
IACS-224 PRODUCTION CHART
AIR-COOLED
Water Temperature (˚F)
Air Temp (˚F)
50
70
80
50
251 lbs.
226 lbs.
214 lbs.
70
226 lbs.
198 lbs.
177 lbs.
90
167 lbs.
150 lbs.
137 lbs.
IACS-227 PRODUCTION CHART
AIR-COOLED
Water Temperature (˚F)
Air Temp (˚F)
50
70
80
50
326 lbs.
295 lbs.
271 lbs.
70
312 lbs.
290 lbs.
267 lbs.
90
263 lbs.
240 lbs.
220 lbs.
SPECIFICATIONS
Model
Refrigerant Standard
Number
Condenser
Type
Electrical
IACS224
Air-Cooled
R-404a
115/60/1
IWCS224 Water-Cooled
R-404a
115/60/1
IACS227 Air-Cooled
R-404a
115/60/1
IWCS227 Water-Cooled
R-404a
115/60/1
Cabinet
Dimensions
Finish
E
KWH
Condenser
Consumption
Water Use
per 100 lbs.
per 100 lbs.
14.3
n/a
70
80
41 lbs.
40 lbs.
40 lbs.
40 lbs.
38 lbs.
35 lbs.
Circuit
Maximum Shipping Operating
Capacity
Fuse Size
Weight
Weight
15
15
110 lbs.
100 lbs.
Cabinet
Dimensions
Finish
Polyethylene
SS
KWH
Condenser
Consumption
Water Use
per 100 lbs.
per 100 lbs.
10.6
n/a
10.5
195
9.8
n/a
7.6
160
WATER-COOLED
Water Temperature (˚F)
Air Temp (˚F)
50
70
50
221 lbs.
179 lbs.
171 lbs.
70
218 lbs.
165 lbs.
155 lbs.
90
164 lbs.
145 lbs.
130 lbs.
WATER-COOLED
Water Temperature (˚F)
Air Temp (˚F)
50
70
50
330 lbs.
300 lbs.
270 lbs.
70
310 lbs.
280 lbs.
260 lbs.
90
280 lbs.
240 lbs.
230 lbs.
Circuit
Maximum Shipping Operating
Capacity
Fuse Size
Weight
Weight
15
15
182 lbs.
146 lbs.
15
15
182 lbs.
146 lbs.
20
20
230 lbs.
198 lbs.
20
20
230 lbs.
198 lbs.
Capacity
Storage Bin
(lbs.)
25
OPERATING LIMITS
Ambient
Water
Water
Temperature Temperature Pressure
50°F-100°F
45°F-90°F
20-120 psi 110-126
Capacity
Storage Bin
( lbs.)
77
77
75
75
80
80
OPERATING LIMITS
Ambient
Water
Water
Temperature Temperature Pressure
50°F-100°F
45°F-90°F
20-120 psi 110-126
50°F-100°F
45°F-90°F
20-120 psi 110-126
50°F-100°F
45°F-90°F
20-120 psi 110-126
50°F-100°F
45°F-90°F
20-120 psi 110-126
Voltage
Range
Voltage
Range

Advertisement