Disassembly

Removal of the Boiler Heat Exchanger Sections

WARNING
The heat exchanger modules may cause injury if
handled improperly. Use suitable lifting equipment
(e.g. crane or gantry).
24
Section 2
(Lag 1)
Section 1
(Lead)
Vitocrossal 300, CA3B Series 2.5 to 6.0 Technical Data
Section 3
(Lag 2)
1. Remove the section mounting nuts.
2. Lift the boiler section from the base frame and place
on a flat clean surface.
3. Repeat for all boiler modules.