Wall Mounted Mini Split Heat Pump Air Conditioner OPERATING AND INSTALLATION MANUAL Model: KFHHP-22-ID / KFHHP-22-OD Indoor Unit. Outdoor Unit. Thank you for selecting Soleus Air. To ensure proper operation, please read this manual and keep it for future reference.
Electrical Schematic Diagram (Indoor Unit)…………………………...……………...………….22 Electrical Schematic Diagram (Outdoor Unit)………..……………………….……………………23 WARRANTY…………………………………………………………………………………………24 Danger Caution. Thank you for selecting Soleus Air. To ensure proper operation, please read this manual and keep it for future reference. TABLE OF CONTENTS This mark indicates a direction/procedure that...
Warning Touching metal parts after removing filter can ★ cause an electric shock. Don’t operate the air conditioner with web ★ hands. It can cause an electric shock. If your air conditioner malfunctions, ★ discontinue use and call your authorized dealer.
◆Instructions before Use Don’t attempt to repair the air conditioner by ★ yourself. There are no user replaceable parts. Please contact your authorized dealer. Be sure to turn the power off when not using the ★ air conditioner for a long time.
◆Remote Control Operation (Continued) The General Procedure: 1. Press ON/OFF button to start the unit. 2. Press MODE button to select the suitable operation mode. 3. Press SWING button to swing. It will stop when pressed again. 4. Press FAN button to set desired fan speed. 5.
Don’t leave windows and doors open for a long ★ time while operating the air conditioner. It can decrease the air conditioning efficiency. Don’t use the air conditioner for other purposes, ★ such as drying clothes, preserving foods, etc. The airflow direction can be adjusted.
Never sprinkle water on the indoor unit and the outdoor unit for cleaning because it can cause an electric shock. Volatile Liquid (e.g. thinner or gasoline) will damage the air conditioner. (So wipe the units with a dry soft cloth, or a cloth slightly moistened with water or cleanser.) Take down the surface panel and clean it (Take it down before cleaning) 1.
2. Turn main power off. 3. Clean dust from the outdoor unit. ◆Trouble Shooting Warning: Don’t attempt to repair the air conditioner by yourself; it can cause an electric shock or fire. Please check the following items before calling your service technician. Problem Won’t start immediately...
Page 12
Sound of water flow can be heard during operation. Mist is emitted during cooling operation. Creaking noise can be heard when start or stop the unit. Air conditioner does not operate at all. Cooling (Heating) efficiency is not good. Remote control is not operating...
Working temperature range Maximum cooling Minimum cooling Maximum heating Minimum heating KFHHP-22-ID / KFHHP-22-OD 22000 / 6450 (2250-7000) 24200 / 7100 (1650-8500) Indoor unit :46.38” ×12.83” × 8.98” Outdoor unit:37.40” × 33.07” × 16.54” Indoor side DB/WB(°F) Outdoor side DB/WB(°F)
◆Installation Location Indoor Unit 1. The inlet and outlet should not be covered so that the outflow air can reach all parts of the room. 2. Install in a location from which the condensation water can be drained out conveniently. 3.
Page 16
◆Installation 1. Always mount the rear panel horizontally. Because the mouth of drainage pipe is at the left side and the left side of the rear panel is better to adjust slightly lower. 2. Fix the rear panel on the selected location with screws supplied with the unit.
◆Installation Note: The power of indoor unit is supplied by the outdoor. A breaker needs to be installed for safety. Operation Procedures: 1. Open the surface panel. 2. Open the cover and cover plate of electric box. (Right figure) 3. Remove the receiving window as shown in the below left figure.
3. Incorrect wiring will cause the unit to malfunction. 4. Units that are not properly grounded are hazardous and may cause the unit to fail. Wire Capacitance of air Model switch KFHHP-22 Electric Wiring NOTE: Power wire Grounding min of unit min.
◆Installation Operation Procedures: • Open the cover of outdoor unit. • The connecting wire led from the terminal board of indoor unit should be connected correctly. • The connecting wire should be a little longer so that it can easily maintained. 1.
◆Installation 1. Remove the front side plate. 2. Break through the hole for wires and put on the rubber bushing. 3. Pull all wires through the rubber bushing. 4. Remove the wire clamp and connect the end of the power connection cord with screws to the wiring terminal board according to the “WIRING DIAGRAM”...
◆Installation Install the connection pipe: • Align the center of the piping flare with the valve. • Screw in the flare nut by hand and then tighten the nut with spanner and torque wrench refer to right figure. Note: Exceeding tightening torque will damage the flare nut. Tightening Torque Table Hex Nut Diameter (mm) φ12...
Page 22
◆Installation 1. Connect charging hose of manifold value to charging end of low pressure valve (both high/low pressure valves must be tightly shut). 2. Connect joint of charging hose to vacuum pump. 3. Fully open handle of Lo manifold valve. 4.
(4) All the impurities such as scraps must be cleared from the unit. 2. Test Operation Method (1) Switch on power and press “ON/OFF” button on the remote control to run the air conditioner. (2) Press “MODE” button and check the operation condition of COOL, HEAT, SWING mode and so forth.
WARNING WHEN THE UNIT IS RUNNING OR STOPED IN 2 MINUTES OR THE VOLTAGE LESS THAN 50V BETWEEN P AND N OF IPM,PLEASE DON'T TOUCH ANY TERMINAL,AVOIDING ELECTRICAL SHOCK HAZARD. N(1) 10BK 35BN FILTER X105 X107 AC-L 30YE/GN AC-N X103 28YE/GN 27YE/GN COMP HEATER...
This warranty does not apply to repairs or replacements necessitated by any cause beyond the control of Soleus International including, but not limited to, any malfunction, defect or failure caused by or resulting from unauthorized service or parts, improper maintenance, operation contrary to furnished instructions, shipping or transit accidents, modification or repair by the user, abuse, misuse, neglect, accident, incorrect power line voltage, fire, flood or other Acts of God, or normal wear and tear.