  • Page 1 13 SEER Mini Split Air Conditioner with Heat Pump and Back up Electric Heat Strip KFTHP-12-ID/KFTHP-12-OD KFTHP-18-ID/KFTHP-18-OD KFTHP-24-ID/KFTHP-24-OD 3119233...
  • Page 2: Table Of Contents

    If you dont press any button within 10 seconds, the remote controller is pre-set as Heat Pump automatically. Note: If the air conditioner you purchased is a Cooling Only one, but you pre-set the remote controller as Heat Pump, will operate properly in cooling.
  • Page 3: Safety Precautions

    Notes:For the purpose of innovation and improvement,above products are subject to change without prior notice. The air conditioner is not a toy , please keep away from children. the laundry area. Be sure to follow this instruction.
  • Page 4: Identification Of Parts

    Identification of Parts Indoor Unit Outdoor Unit The figures in this manual are based on the external view of a standard model. Consequently, the shape may differ from that of the air conditioner you have selected. Air Intake Front Panel Emergency Panel...
  • Page 5: Remote Controller

    Identification of Parts Operating and Display Run Indicator It is on during operation. Power Indicator It lights up when power supply is on. The above operating sketch map is suitable for Z Signal Receives Receive signal from the remote control. Sleep Indicator It lights up during the set sleep function...
  • Page 6 Remote Control Remote Control The remote control transmits signals to the system. ON/OFF button Used to start and stop operation . TIMER button Used to select TIMER operation. UP button (TOO COOL button) Used to increase the set room temperature and time(0.5~24h or 1~12h ).
  • Page 7 Remote Control Remote Control Some remote control s display: SLEEP TIMER ON TMIER OFF AUTO FEEL HIGH COOL HEAT SWING Style.1 FEEL AUTOQUIET COOL POWERFUL AUTO DELAY HEAT HEALTHY TIMER Style.5 Note:The above remote control is only for reference, subject to the When inserting the batteries for the first time or each time the batteries are replaced...
  • Page 8 Note: The remote control holder is an optional part. Remote control holder How to Use To operate the room air conditioner, aim the remote control to the signal receptor. The remote control will operate the air conditioner at a distance of up to 10 feet when pointing at signal receptor of indoor unit.
  • Page 9: Operation Instructions

    Operation Instructions FEEL mode operation procedure Operates by selecting automatically the operation mode(HEAT,DRY,FAN,COOL)depending on the room temperature during staring. With the remote control pointing toward the air conditioner. Turning on Press button, when the appliance receives the ON/OFF signal, the RUN indicator of the indoor unit lights up.
  • Page 10 Operation Instructions TIMER mode It is convenient to set the timer on with TIMER button when you go out in the morning to achieve a comfortable room temperature when you get home. You can also set timer off at night to enjoy a good sleep. When the Remote Control is OFF,press the TIMER button to set...
  • Page 11: Maintenance

    After cleaning, dry well in shade. Close the front panel again. Clean the air filter every two weeks if the air conditioner operates in an extremely dusty environment. At the beginning of the season Make sure there are no obstacles blocking...
  • Page 12: Protection

    96 f instead of 96 f If the air conditioner runs in COOLING or DRY mode with door or window opened for a long time when relative humidity is above 80%,dew may drip down from the outlet. Features of protector The protective device will work as follows.
  • Page 13: Troubleshooting

    If batteries in the remote controller exhausted. If the protective device works to protect the appliance. If the protector trip or fuse is blown. Are the intakes and outlets of the air conditioner blocked Is the temperature set properly Is the air filter dirty?
  • Page 14: Installation Instructions

    Installation Instructions Installation Diagram Distance from wall should be over 6”” Distance from floor should be over Air intake distance from the wall should be 12” over NOTE NOTE Above figure is only a simple presentation of the unit, it may not match the external appearance of the unit you purchased.
  • Page 15 Installation Instructions Connecting of the Cabble Wiring between the indoor and outdoor units: 1) Remove the PCB cover from the indoor unit; 2) Refer to the wiring diagram attached to indoor unit when connecting cords to indoor unit terminals; 3) Reinstall the PCB cover. Be sure that side B is facing outside.
  • Page 16 Installation Instructions Indoor Unit Installation 1. Installing the Mounting Plate Decide an installing location for the mounting plate according to the indoor unit location and piping direction. Keep the mounting plate horizontally with a horizontal ruler or dropping line. Drill holes of in depth on the wall for fixing the plate.
  • Page 17 Installation Instructions NOTE NOTE Piping Joints Thermal Insulation: Wrap the piping joints with thermal insulation materials and then wrap with a vinyl tape. The temperature of refrigerant circuit will be high, please keep the interconnection able away from the copper tube. Piping Thermal Insulation: a.
  • Page 18 Caution: 1. Never fail to have an individual power circuit specifically for the air conditioner. As for the method of wiring, refer to the circuit diagram posted on the inside of the access door . 2.Comfirm that the cable thickness is as specified in the power source specification.
  • Page 19: Vacuum Pump

    Installation Instructions Outdoor Unit Installation 1.Install Drain Port and Drain Hose (for heat-pump model only) The condensate drains from the outdoor unit when the unit operates in heating mode. In order to protect the environment, install a drain port and a drain hose to direct the condensate water. Just install the drain port and rubber washer to the chassis of the outdoor unit, then connect a drain hose to the port as the right figure shown.
  • Page 20 Installation Instructions Interconnection Cable Take off the cover for Interconnection cable of outdoor unit. Take off the block for Interconnection cable, then put the core of the power wire to the terminal and fix it according to the diagrams pasted to indoor and outdoor unit separately. Fix the accessory cable with the Interconnection cable block.
  • Page 21 Check if there is leakage of refrigerant. ATTENTION: If there is no power plug along with the air conditioner,The power cord should be connected to an air switch ,whose current carrying capacity should be more than 20A and the minimum open-circuit...
  • Page 22 Model:KFTHP-12-ID Model:KFTHP-12-OD...
  • Page 23 Model:KFTHP-18-ID Model:KFTHP-18-OD...
  • Page 24 Model:KFTHP-24-ID Model:KFTHP-24-OD...