Technical Information
DIMENSIONS
WEIGHT
ELECTRICAL SUPPLY:
POWER CONSUMPTION:
FAN MOTOR:
LAMP:
SUITABLE FOR INSTALLATION
ABOVE:
The symbol
on the product or on its packaging indicates that this product may not be treated as household waste. Instead it shall be handed
over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly,
you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate
waste handling of this product. For more detailed information about recycling of this product, please contact your local city office, your household
waste disposal service or the shop where you purchased the product.
WARNING: DOUBLE INSULATED DO NOT
EARTH

Electrical Requirements

Any permanent electrical installation must comply with
the latest I.E.E. Regulations and local Electricity Board
regulations. For your own safety this should be under-
taken by a qualified electrician e.g. your local Electricity
Board, or a contractor who is on the roll of the National
Inspection Council for Electrical Installation Contracting
(NICEIC).

Electrical Connection

Before connecting to the mains supply ensure that the
mains voltage corresponds to the voltage on the rating
plate inside the cooker hood.

INSTALLATION INSTRUCTIONS

HEIGHT:
WIDTH:
DEPTH:
DEPTH WITH VISOR OPEN:
GROSS:
NET:
Voltage (50Hz)
ELECTRIC HOB:
GAS HOB:
SLOT-IN GAS COOKER
SLOT-IN ELECTRIC COOKER
Note: CE Marking certifies that this appliance complies with the requirements
laid down in EEC directive 89:336. (Electromagnetic compatibility) and subse-
quent modifications and Low Voltage directive 72/23/E.
ELECTRICAL CONNECTIONS
This appliance is fitted with a 2 core mains cable and
must be permanently connected to the electricity supply
via a double-pole switch having 3mm minimum contact
gap on each pole. A Switched Fuse Connection Unit to
BS1363 Part 4, fitted with a 3 Amp fuse, is a recom-
mended mains supply connection accessory to ensure
compliance with the Safety Requirements applicable to
fixed wiring instructions.
This appliance conforms to BS 800: 1988 and EEC
Directive No. 78 308 regarding suppression of radio and
television interference.
10
150mm
598mm
482mm
525mm
8,9 kg
7,9 kg
220-240 V
135W
95W
40W
7KW (max)
10KW (max)
13.5KW (max)
12.4KW (max)