Toshiba RAS-10S3AV-E Service Manual page 60

Hide thumbs Also See for RAS-10S3AV-E:
Table of Contents

Advertisement

CAUTION
· Wrong wiring connection may cause some electrical
parts burn out.
· Be sure to comply with local cords on running the
wire from indoor unit to outdoor unit (size of wire
and wiring method, etc.).
· Every wire must be connected firmly.
·
This installation circuit breaker must be used specified
for the power supply line of this air conditioner.
· If incorrect or incomplete wiring is carried out, it will
cause an ignition or smoke.
· Prepare the power supply for exclusive use with the
air conditioner.
· This product can be connected to the mains.
Connection to fixed wiring: A switch which
disconnects all poles and has a contact separation of
at least 3 mm must be incorporated in the fixed wiring
NOTE : Connecting cable
• Wire type : More than H07RN-F or 60245 IEC66
(1.5 mm
2
or more).
10-6 Others
10-5-1. Gas leak test
• Check the flare nut connections, valve stem cap
connections and service port cap connections for
gas leak with a leak detector or soap water.
Check places for
the indoor unit.
Check places for
the outdoor unit.
Fig. 10-5-1
10-6 -2 . Remote Control A-B Selection
• When two indoor units are installed in the same room or
adjacent two rooms, if operating a unit, two units may
receive the remote control signal simultaneously and
operate. In this case, the operation can be preserved
by setting either one remote control to B setting.
(Both are set to A setting in factory shipment.)
• The remote control signal is not received when the
settings of indoor unit and remote control are different.
• There is no relation between A setting/B setting and A
room/B room when connecting the piping and cables.
<Remote control A-B selection>
To separate using of remote control for each indoor unit
in case of 2 air conditioners are installed nearly.
<Remote Control B Setup>
1. Press [RESET] button on the indoor unit to turn the air
conditioner ON.
2. Point the remote control at the indoor unit.
3.
Push and hold [CHECK] button on the Remote Control
by the tip of the pencil. "00" will be shown on the display
(Picture
)
1
4. Pres s [ MODE] during pushing [CHECK]. "B" will show
on the display and "00" will disappear and the air
conditioner will turn OFF. The Remote Control B
is memorized [Picture
NOTE : 1. Repeat above step to reset Remote
Control to be A.
2. Remote Control A has not "A" display.
3. Default setting of Remote Control from
factory is A.