7-2. Operation Data
<Cooling>
Tempeature
Model name
condition(°C)
RAS-
Indoor
Outdoor
27/19
35/-
10S3KV-E
<Heating>
Tempeature
Model name
condition(°C)
RAS-
Indoor
Outdoor
20/-
7/6
10S3KV-E
NOTES :
1. Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.
(Thermistor themometer)
2. Connecting piping condition : 5 m
Heat exchanger
Standard
pipe temp.
pressure
P (MPa)
T1 (°C)
0.9 to 1.0
11 to 12
Heat exchanger
Standard
pipe temp.
pressure
P (MPa)
T1 (°C)
2.4 to 2.5
40 to 41
– 20 –
Indoor
fan mode
T2 (°C)
48 to 49
High
Indoor
fan mode
T2 (°C)
0 to 1
High
FILE NO. SVM-15001
Outdoor
Compressor
fan mode
revolution
(rps)
High
51
Outdoor
Compressor
fan mode
revolution
(rps)
High
65