25. TROUBLESHOOTING

Below is a list of some of the possible malfunctions.
If the problem cannot be resolved as described, contact Customer Services.
PROBLEM
The coffee is not hot.
The water circuit is empty
The inside of the appliance is very dirty
The infuser (A8) has not been replaced
after cleaning
Indicates the steam/hot water dial (A22)
must be turned
The machine must be descaled
OK
POSSIBLE CAUSE
The cups were not preheated.
The internal circuits of the appliance have
cooled down because 2/3 minutes have
elapsed since the last coffee was made.
A low coffee temperature is set.
Turn the steam/hot water dial (A22) to the I posi-
tion until delivery stops, then bring it back to the
0 position. If the alarm occurs while hot water or
steam is being delivered, turn the dial to the 0
position. Turn the steam/hot water dial to the I
position until delivery stops, then bring it back to
the 0 position. If the problem persists, make sure
the water tank (A17) is fully inserted.
Clean the inside of the appliance thoroughly,
as described in section "18. Cleaning". If the
message is still displayed after cleaning, contact
Customer Services.
Insert the infuser as described in section "18.9
Cleaning the infuser".
Turn the steam/hot water dial.
The descaling procedure needs to be performed
as soon as possible (see section "19. Descaling").
REMEDY
Warm the cups by rinsing them with hot
water (Please note: you can use the hot
water function).
Before making coffee, rinse the internal
circuits by pressing the
Set a higher coffee temperature in
the menu (see section "9. Setting
temperature").