Safety Precautions - Bosch Worcester Greenstar CDi Classic System ErP Series Installation, Commissioning And Servicing Instructions

Wall hung rsf gas fired condensing system boiler
Table of Contents

Advertisement

KEY TO SYMOLS AND SAFETY PRECAUTIONS
1.2

Safety precautions

If you smell gas
A gas leak could potentially cause an explosion. If you smell gas, observe
the following rules.
▶ Prevent flames or sparks:
– Do not smoke, use a lighter or strike matches.
– Do not operate any electrical switches or unplug any equipment.
– Do not use the telephone or ring doorbells.
▶ Turn off the gas at the meter.
▶ Open windows and doors.
▶ Warn your neighbours and leave the building.
▶ Prevent anyone from entering the building.
▶ Well away from the building: call the National Gas Emergency Service
on 0800 111 999.
BOILER OPERATION:
This boiler must only be operated by a responsible adult who has
been instructed in, understands and is aware of the boiler's
operating conditions and effects.
provided with the correct equipment for their needs, that it is installed,
commissioned and serviced in accordance with the manufacturer's
instructions by competent persons and that it meets the requirements of
the appropriate Building Regulations. The Benchmark Checklist can be
used to demonstrate compliance with Building Regulations and should
be provided to the customer for future reference.
Installers are required to carry out installation, commissioning and
servicing work in accordance with the Benchmark Code of Practice
which is available from the Heating and Hotwater Industry Council who
manage and promote the scheme.
Visit centralheating.co.uk for more information.
HEALTH AND SAFETY
The appliance contains no asbestos and no substances have been used
in the construction process that contravene the COSHH Regulations
(Control of Substances Hazardous to Health Regulations 1988).
COMBUSTIBLE AND CORROSIVE MATERIALS:
Do not store or use any combustible materials (paper, thinners, paints
etc.) inside or within the vicinity of the boiler.
Chemically aggressive substances can corrode the appliance and
invalidate any warranty.
FITTING & MODIFICATIONS
Fitting the appliance and any controls to the appliance may only be
carried out by a competent engineer in accordance with the current Gas
Safety (Installation and Use) Regulations.
Flue systems must not be modified in any way other than as described in
the fitting instructions. Any misuse or unauthorised modifications to the
appliance, flue or associated components and systems could invalidate
the warranty. The manufacturer accepts no liability arising from any
such actions, excluding statutory rights.
SERVICING
Advise the user to have the system serviced annually by a competent,
qualified Gas Safe registered engineer. Approved spares must be used
to help maintain the economy, safety and reliability of the appliance.
IMPORTANT
The service engineer must complete the Service Record on the
Benchmark Checklist after each service.
4
Benchmark places
responsibilities on both
manufacturers and
installers. The purpose is to
ensure that customers are
INSTALLATION REGULATIONS
Current Gas Safety (Installation & Use) Regulations:
All gas appliances must be installed by a competent person in
accordance with the above regulations. Failure to install appliances
correctly could lead to prosecution.
The appliance must be installed in accordance with, and comply to, the
current: Gas Safety Regulations, IET Regulations, Building Regulations
(England), Building Standards (Scotland) (Consolidation), Building
Regulations (Wales), Building Regulations (Northern Ireland), local
water by-laws, Health & Safety Document 635 (The Electricity at Work
Regulations 1989) and any other local requirements.
EU Regulations No. 811/2013 - Energy Labelling.
British Standards:
Where no specific instruction is given, reference should be made to the
relevant British Standard codes of Practice.
BS7074:1 - Code of practice for domestic and hot water supply
BS6891 - Installation of low pressure gas pipe work up to 28mm (R1)
BS5546 - Installation of gas hot water supplies for domestic purposes
EN12828 - Central heating for domestic premises
BS5440:1 - Flues and ventilation for gas appliances of rated heating not
exceeding 70kW (net): Flues
BS5440:2 - Flues and ventilation for gas appliances of rated heating not
exceeding 70kW (net): Air Supply
BS7593 - Treatment of water in domestic hot water central heating
systems
BS6798 - Installation of gas fired boilers of rated input up to 70kW (net)
Irish Standards
The relevant Irish standards should be followed, including:
• ECTI National rules for electrical installations
• IS 813:2002 for Domestic Gas Installations.
LPG Installations
An appliance using L.P.G. must not be installed in a room or internal
space below ground level unless one side of the building is open to the
ground.
Timber framed building:
Where the boiler is to be fitted to a timber framed building the guidelines
laid down in BS5440: Part 1 and IGE "Gas Installations in Timber Frame
Buildings" should be adhered to.
Potable water:
All seals, joints and compounds (including flux and solder) and
components used as part of the secondary domestic water system must
be approved by WRAS.
CH Water:
Artificially softened water must not be used to fill the central heating
system.
6 720 815 724 (2015/11)

Advertisement

Table of Contents
loading

Table of Contents